1473783.1
:
Pillar Axiom: Capacity usage in the GUI does not match when adding up lun size capacity usage
Related Items |
- Pillar Axiom 600 Storage System
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Pillar Axiom>SN-DK: Ax600
|
In this Document
Created from <SR 3-5865232121>
Applies to:
Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
The usage in the GUI does not match the actual size of the luns.
Fix
LUN09_Prod_Svrs_OS: Medium 5 1537 Brick001
LUN10_File_Svcs: Medium 5 1950 Brick001
LUN02: Low 5 402 Brick001
These total 3889GB, they are at standard redundancy or raid 5 SATA, so the space used is 1.2 times the lun size.
3889 * 1.2 = 4667 which is what the GUI shows.
On a raid 5 FC, the multiplier would be 1.1.