Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1473783.1
Update Date:2012-08-27
Keywords:

Solution Type  Technical Instruction Sure

Solution  1473783.1 :   Pillar Axiom: Capacity usage in the GUI does not match when adding up lun size capacity usage  


Related Items
  • Pillar Axiom 600 Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Pillar Axiom>SN-DK: Ax600
  •  




In this Document
Goal
Fix
References


Created from <SR 3-5865232121>

Applies to:

Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

The usage in the GUI does not match the actual size of the luns.
 

Fix

LUN09_Prod_Svrs_OS: Medium 5 1537 Brick001
LUN10_File_Svcs: Medium 5 1950 Brick001
LUN02: Low 5 402 Brick001

These total 3889GB, they are at standard redundancy or raid 5 SATA, so the space used is 1.2 times the lun size.
3889 * 1.2 = 4667 which is what the GUI shows.
 

On a raid 5 FC, the multiplier would be 1.1.

References

<NOTE:1392714.1> - Pillar Axiom: Brick Zeroing Rates for Storage Reclimation

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback