Solution Type  Technical Instruction Sure

Solution  1473741.1 :   SL48 - When a SL48 Chassis is Replaced, Does The Serial Number Change  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Goal
Fix


Applies to:

Sun StorageTek SL48 Tape Library - Version All Versions and later
Information in this document applies to any platform.

Goal

SL48 - When a SL48 Chassis is Replaced, Does The Serial Number Change 

Fix

When you replace the SL48 chassis, the chassis S/N is recorded on the Robot and the controller card.  With a chassis FRU replacement, the original SL48 controller card is installed in the new FRU chassis, on power up the OCP will ask:

Identity Data Mismatch
Serial No. Mismatch between
Chassis and Controller

Use Data From:  Chassis/Controller

The front panel up and down buttons will select whichever S/N you want.  Should always chose Chassis to keep the FRU chassis S/N.