Solution Type Technical Instruction Sure Solution 1466759.1 : Sun StorEdge S1 Array: How to Replace the whole system FRU:ATR:1466759.1:0
In this Document
Applies to:Sun Storage S1 Array - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalHow to Replace the Sun StorEdge S1 Array.
FixDISPATCH INSTRUCTIONS If it does you can start at step 3.)
2.) Power off the attached host if necessary (see the Note 1). 3.) Power off the Sun StorEdge S1 Array. 4.) Discconnect the SCSI and power cables of the array that you are going to remove. 5.) Remove the drives from the array and pay attention to their originial position. 6.) Remove the array from the rack.
7.) Install the new Sun StorEdge S1 array. 8.) Re-attach the SCSI and power cables. 9.) Re-install the drives in their original position. 10.) Power on the Sun StorEdge S1 Array 11.) Power on the host (if necessary, see Note 1) 12.) Check the accessibility of the drives.
- 540-4952 Sun StorEdge S1 - DC version without disks