Goal
How to replace a Netra T5440 SAS Expander Board
********************************************************************************************************************************************
To report errors or request improvements on this procedure, please go to http://support.us.oracle.com and put a comment on Doc ID: 1464127.1
********************************************************************************************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner
TIME ESTIMATE: 30 minutes
Task Complexity: 0
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: Defective SAS Expander Board
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
A data backup is not a pre-requisite but is a wise precaution.
System needs to be shutdown by customer
Remove the SAS Expander Board:
1. Remove the top cover,
2. Remove Fan Tray 1.
3. Remove PCI cards in slots 1-4, & note thier possitions & external cabling.
4. Remove the SAS Expander board (make note of the SAS cable connection).
Install the SAS Expander Board:
1. Install the SAS Expander board & place the SAS cable in its original poition.
2. Install the PCI cards into Slots 1-4 in their original position with original cables.
3. Install Fan Tray 1.
4. Install the top cover.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Turn on the system and verify functionality.
PARTS NOTES: https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#exploded_view
REFERENCE INFORMATION: http://docs.oracle.com/cd/E19874-01/index.html