Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1464125.1
Update Date:2012-06-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1464125.1 :   How to replace a Netra T5440 PCI Auxiliary Board:ATR:1464125.1:0  


Related Items
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to replace a Netra T5440 PCI Auxiliary Board

********************************************************************************************************************************************
To report errors or request improvements on this procedure, please go to http://support.us.oracle.com and put a comment on Doc ID: 1464125.1
********************************************************************************************************************************************

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner

TIME ESTIMATE: 30 minutes

Task Complexity: 0

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:  Defective PCI Auxiliary Board

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
A data backup is not a pre-requisite but is a wise precaution.
System needs to be shutdown by customer

Remove the Aux board:

1.  Remove the top cover,

2.  Remove Fan Tray 1.

3.  Remove PCI cards in slots 1-4, & note thier possitions & external cabling.

4.  Remove the SAS Expander board (make note of the SAS cable connection).

5.  Remove the cables attached to the Aux board.

6.  Remove the 6 Screws, & lift the Aux board from the chassis.

 

Install the Aux borad:

1.  Align the Aux board with the 6 standoffs & install the 6 screws.

2.  Connect the Aux card cables.

3.  Install the SAS Expander board & place the SAS cable in its original poition.

4.  Install the PCI cards into Slots 1-4 in their original position with original cables.

5.  Install Fan Tray 1.

6.  Install the top cover.

 

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Turn on the system and verify functionality.


PARTS NOTES:   https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#exploded_view


REFERENCE INFORMATION:  http://docs.oracle.com/cd/E19874-01/index.html


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback