![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1464125.1 : How to replace a Netra T5440 PCI Auxiliary Board:ATR:1464125.1:0
Applies to:Sun Netra T5440 Server - Version Not Applicable and laterInformation in this document applies to any platform. GoalHow to replace a Netra T5440 PCI Auxiliary Board ******************************************************************************************************************************************** FixDISPATCH INSTRUCTIONS 1. Remove the top cover, 2. Remove Fan Tray 1. 3. Remove PCI cards in slots 1-4, & note thier possitions & external cabling. 4. Remove the SAS Expander board (make note of the SAS cable connection). 5. Remove the cables attached to the Aux board. 6. Remove the 6 Screws, & lift the Aux board from the chassis.
Install the Aux borad: 1. Align the Aux board with the 6 standoffs & install the 6 screws. 2. Connect the Aux card cables. 3. Install the SAS Expander board & place the SAS cable in its original poition. 4. Install the PCI cards into Slots 1-4 in their original position with original cables. 5. Install Fan Tray 1. 6. Install the top cover.
OBTAIN CUSTOMER ACCEPTANCE
Attachments This solution has no attachment |
||||||||||||
|