Solution  1462980.1 :   How to Replace a Netra T5440 PCI/XAUI Card:ATR:1462980.1:0  


Related Items
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to replace a Netra T5440 PCI/XAUI card (CRU)

*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1462980.1
*********************************************************************

Fix

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner

TIME ESTIMATE: 30 minutes

Task Complexity: 0

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW: PCIe/XAUI card failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
System needs to be shutdown by customer

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
NOTE: Customer might need to consult the PCIe/XAUI card specific manual for procedure to bring the card into operation

Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTES:  N/A

REFERENCE INFORMATION:   http://docs.oracle.com/cd/E19874-01/index.html