Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Minimal field experience, this is customer replaceable component
TIME ESTIMATE: 30 minutes
Task Complexity: 0
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Hot swappable component normal system recovery protection recommended.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD precautions
A) Remove PSU:
1. Disconnect the power cord from the faulty power supply.
2. Grasp the power supply handle and push the power supply latch to the left while pushing inward on the power supply.
3. Pull the power supply out of the chassis
B) Install PSU:
1. Align the replacement power supply with the empty power supply chassis bay.
2. Slide the power supply into the bay until it is fully seated
3. Reconnect the power cord to the power supply. Verify that the Input Power OK LED is lit. If the system is in operation, the Output On LED should also be lit.
4. On the replaced power supply, verify that the amber Fault LED is not lit.
5. Verify that the System Power Supply Fault LED and the Service Required LED is not lit on the front and rear panels of the server.
6. At the ILOM -> prompt, issue the show faulty command to verify the status of the power supplies.
OBTAIN CUSTOMER ACCEPTANCE
PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#Power
REFERENCE INFORMATION: http://docs.oracle.com/cd/E19874-01/index.html
Attachments