Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1462974.1
Update Date:2012-06-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  1462974.1 :   How to Replace a Netra T5440 Power Supply:ATR:1462974.1:0  


Related Items
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to replace a Netra T5440 Power Suppy

*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1462974.1
*********************************************************************

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Minimal field experience, this is customer replaceable component

TIME ESTIMATE: 30 minutes

Task Complexity: 0

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Hot swappable component normal system recovery protection recommended.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD precautions


A) Remove PSU:

1. Disconnect the power cord from the faulty power supply.

2. Grasp the power supply handle and push the power supply latch to the left while pushing inward on the power supply.

3. Pull the power supply out of the chassis


B) Install PSU:

1. Align the replacement power supply with the empty power supply chassis bay.

2. Slide the power supply into the bay until it is fully seated

3. Reconnect the power cord to the power supply.  Verify that the Input Power OK LED is lit.  If the system is in operation, the Output On LED should also be lit.

4. On the replaced power supply, verify that the amber Fault LED is not lit.

5. Verify that the System Power Supply Fault LED and the Service Required LED is not lit on the front and rear panels of the server.

6. At the ILOM -> prompt, issue the show faulty command to verify the status of the power supplies.


OBTAIN CUSTOMER ACCEPTANCE

PARTS NOTE:  https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#Power

REFERENCE INFORMATION:   http://docs.oracle.com/cd/E19874-01/index.html


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback