How to replace a Netra T5440 PCI Mezzanine Card:ATR:1462838.1:1
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Applies to:
Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a Netra T5440 PCI Mezzanine Card
*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1462838.1
*********************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Netra T5440 Knowledge or field experience with other CMT servers.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: PCI Mezzanine board failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Shut down system and Power down the server then have the server positioned so that interior components can be accessed.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
A. Remove the PCI Mezzanine board:
1. Remove the Top Cover
2. Disconnect the PCI mezzanine cables.
3. Pull the release levers up and back. The release levers unseat the mezzanine from the riser cards.
4. Lift the PCI mezzanine up and out
5. Remove the PCI mezzanine riser cards
a. Press the release tab downward
b. Pull the riser card straight up and out of the chassis
B. Install the PCI Mezzanine board:
1. Install the PCI mezzanine riser cards on the motherboard
a. Carefully place the riser cards on the riser card slots.
b. Press down until fully seated into slots.
2. Carefully seat the PCI mezzanine on the PCI riser cards.
3. Secure the release tabs by pressing them forward and down. Securing the release tabs fully seats the PCI mezzanine onto the riser cards. You do not need to press downward.
4. Reconnect the PCI mezzanine cables
5. Install the top cover
OBTAIN CUSTOMER ACCEPTANCE:
WHAT ACTION DOES THE FE/CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
* If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: https://support.us.oracle.com/handbook_internal/Systems/Netra_T5440/components.html#I/O
REFERENCE INFORMATION: http://docs.oracle.com/cd/E19874-01/index.html