How to Replace a Netra T5440 Fan:ATR:1462818.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Applies to:
Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a Netra T5440 CPU fan
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1462818.1
********************************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner is required.
TIME ESTIMATE: 30 minutes
Task Complexity: 0
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The host should be shut down & power removed.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
A) Remove a Fan Module FT0 or 1
1. Remove the top cover
2. Squeeze the fan's release latch & lift fan out of chassis
B) Install a Fan Module FT0 or 1
1. Squeeze the fan's release latch & lower the fan into position
2. Attach the top cover
===================================
C) Remove a Fan Module FT2
1. Loosen the Green captive screw then remove FT2.
D) Install a Fan Module FT2
1. Insert FT2 then tighten the green captive screw.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: N/A
PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#Fan