How to Remove and Replace the SPARC T6320 Server Module Assembly:ATR:1462372.1:0
Related Items |
- Sun Blade T6320 Server Module
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Blade T6320 Server Module - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and Replace the SPARC T6320 Server Module Assembly
********************************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1462372.1
********************************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T6320 training is desirable but not required
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: Failed T6320 server module assembly
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Shut Down the Oracle Solaris OS
Prepare the Server Module for Removal
Remove the Server Module From the Modular System
Remove the Cover
ESD Safety Measures
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare to take all ESD precautions when working with both the original server module and the new enclosure assembly.
2. Prepare to place all components on an antistatic mat unless you install each component immediately in the new enclosure assembly.
3. Remove the top cover from the original server module and the new enclosure assembly.
4. Transfer the drives from the original server module to the enclosure assembly.
Caution - You must return each HDD to the bay from which it was removed. Use an adhesive note or another method to temporarily label the HDDs after you remove them
5. Transfer the drive fillers from the original server module to the enclosure assembly.
6. Transfer the SP card from the original server module to the enclosure assembly.
7. Transfer the DIMMs from the original server module to the enclosure assembly.
Move each DIMM to the same slot in the enclosure assembly.
8. Attach the cover to the enclosure assembly.
9. Insert the completed enclosure assembly in the same slot as the original server module.
10. Start the server module host.
12. Perform diagnostics to verify the proper operation of the server module.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear
component faults.
* If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunBladeT6320/SunBladeT6320.html
REFERENCE INFORMATION:
SPARC T6320 Server Module Service Manual at http://docs.oracle.com/cd/E19745-01/820-2386-12/index.html