![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1455862.1 : How to Replace a Sun Blade X3-2B(X6270M3) and Netra Blade X3-2B(Netra X6270M3) RAID Expansion Module Cache Battery:ATR:1455862.1:0
In this Document
Applies to:Netra Blade X3-2B - Version Not Applicable and laterSun Blade X3-2B - Version Not Applicable and later Information in this document applies to any platform. GoalHow to remove and replace a RAID Expansion Module (REM) Cache Battery in a Sun Blade X6270M3 Server Module or Netra X6270M3 Server Module. FixDISPATCH INSTRUCTIONS TASK COMPLEXITY: 0 DELIVERY REQUIREMENT: Caution - After removing the server from the chassis insert a filler panel into an empty slot to reduce the possibility of a system shutdown. 6. Remove the existing REM card by pulling the REM card out at an angle away from the support bracket. 7. Turn the REM over and place on an anti-static mat. 8. Unplug the battery connector from the REM card. 9. Remove the three screws securing the old REM battery to the card and remove the battery. 10. Attach the new battery to the REM card and insert the three screws to secure the battery. 11. Attach the battery connector from the battery to the REM card. 12. Close the REM latch downwards. 13. Slide the new REM card at an angle into the support bracket in the server module, then press it carefully into the connector.
Attachments This solution has no attachment |
||||||||||||||
|