Asset ID: |
1-71-1455446.1 |
Update Date: | 2012-07-20 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1455446.1
:
How to Replace a Sun Blade X3-2B(X6270M3) and Netra Blade X3-2B(Netra X6270M3) Hard Disk Drive:ATR:1455446.1:0
Related Items |
- Netra Blade X3-2B
- Sun Blade X3-2B
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X3-2B - Version Not Applicable to Not Applicable [Release N/A]
Netra Blade X3-2B - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a Hard Disk Drive in a Sun Blade X6270M3 Server Module or Netra X6270M3 Server Module.
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required
TASK COMPLEXITY: 0
DELIVERY REQUIREMENT: Immediate
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
X6270 M3 Server Module drives are hot-swappable or hot-pluggable depending on the RAID configuration, which means that you can remove them while the server is running. However, you must prepare the operating system on the server prior to removing the drives if they are not setup in a hardware RAID configuration.
Caution -- Possible data loss: If you insert a storage device that has been configured with a RAID volume into a server that did not previously have its storage devices configured with RAID volumes, the existing storage devices in the server will be converted to RAID volumes during automatic synchronization and any data on the existing storage devices in the server are erased. You should delete the active RAID volume from the storage device. For information on how to delete a RAID volume, use the appropriate RAID management utility for the RAID controller installed.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace an Existing Hard Disk Drive (HDD).
1. Prepare the server module operating system, as required, before you remove drives.
2. Observe the LEDs on the front panel of the drive to verify which drive in the server is faulty.
- Green (operational) / amber (faulty disk ) / blue (HDD has been prepared for removal)
3. To remove the faulty drive from the server,
a. Press the release lever button on the drive front panel then tilt the lever into a fully opened position.
b. Hold the opened release lever and gently slide the drive toward you.
c. If you are not immediately replacing the drive, insert a filler panel into the empty drive slot on the server.
4. To install (or replace) the drive,
a. Slide the drive into the vacant slot by pressing the middle of the drive faceplate with your thumb or finger.
c. Using your thumb or finger, press on the middle of the drive faceplate until the release lever engages with the chassis.
d. Close the release lever until it clicks into place and is flush with the front of the server.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
For hot plug, configure the drive and verify drive availability.
Use appropriate software commands to re-activate/re-sync mirror if manual intervention is required.
PARTS NOTE:
REFERENCE INFORMATION:
Sun Blade X6270 M3 Server Module Service Manual
http://docs.oracle.com/cd/E20881_01/index.html
Sun Netra X6270 M3 Server Module Service Manual
http://docs.oracle.com/cd/E26403_01/index.html
Detailed SVM instructions can be found at
http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions
Attachments