Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1455320.1
Update Date:2012-07-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1455320.1 :   How to Replace a Sun Blade X3-2B(X6270M3) and Netra Blade X3-2B(Netra X6270M3) Fabric Expansion Module:ATR:1455320.1:0  


Related Items
  • Netra Blade X3-2B
  •  
  • Sun Blade X3-2B
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Netra Blade X3-2B - Version Not Applicable and later
Sun Blade X3-2B - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a Fabric Expansion Module (FEM) in a Sun Blade X6270M3 Server Module or Netra X6270M3 Server Module.

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field Engineer skills

TASK COMPLEXITY: 0

DELIVERY REQUIREMENT:
Schedule with maintenance window

TIME ESTIMATE: 30 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace a FEM Card

1. Power off the server module.

2. Remove the server module from the chassis and lay it flat cover side up on an anti-static mat.
Caution - After removing the server from the chassis insert a filler panel into an empty slot to reduce the possibility of a system shutdown.
3. Remove the cover from the server module.
4. Perform one of the following:
* Remove the existing FEM board.  To remove an existing FEM pull the board up at an angle from the opposite end not in the support bracket.
or
* Remove protective shipping cap from the FEM connector.
5. Perform the following steps to install the FEM board:
a. Slide the FEM board at an angle into the support bracket.

  Note – Always install a single width form factor FEM in FEM 0.
b. Press the FEM board carefully into the connector.
6. Install the cover on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:

Sun Blade X6270 M3 Server Module Service Manual
http://docs.oracle.com/cd/E20881_01/index.html

Sun Netra X6270 M3 Server Module Service Manual
http://docs.oracle.com/cd/E26403_01/index.html

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.