Goal

How to Remove and Replace a SPARC T4-1B Hard Drive

***************************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1455292.1
***************************************************************************

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T4-1B training is desirable but not required (this is a CRU procedure)

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:  replace failed hard drive

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

T4-1B Server Module drives are hot-swappable, which means that you can remove them while the server is running. However, you must prepare the operating system on the server prior to removing the drives.

NOTE: Please be aware that Disks could be in hardware raid volumes. When replacing a failed drive in a hardware RAID volume, follow the T4-1B RAID Drive Replacement Strategies at: http://docs.oracle.com/cd/E22735_01/html/E22736/z400086d1535370.html#scrolltoc

Caution -- Possible data loss: If you insert a storage device that has been configured with a RAID volume into a server that did not previously have its storage devices configured with RAID volumes, the existing storage devices in the server will be converted to RAID volumes during automatic synchronization and any data on the existing storage devices in the server are erased.You should delete the active RAID volume from the storage device. For information on how to delete a RAID volume, use the appropriate RAID management utility for the RAID controller installed.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Replace an Existing Hard Disk Drive (HDD).

1. Observe the LEDs on the front panel of the drive to verify which drive in the server is faulty.

- Green (operational) / amber (faulty disk ) / blue (HDD has been prepared for removal)

2. To remove the faulty drive from the server,

a. Press the release lever button on the drive front panel then tilt the lever into a fully opened position.

b. Hold the opened release lever and gently slide the drive toward you.

c. If you are not immediately replacing the drive, insert a filler panel into the empty drive slot on the server.

3. To install (or replace) the drive,

a. Slide the drive into the vacant slot by pressing the middle of the drive faceplate with your thumb or finger.

c. Using your thumb or finger, press on the middle of the drive faceplate until the release lever engages with the chassis.

d. Close the release lever until it clicks into place and is flush with the front of the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

For hot plug, configure the drive and verify drive availability.
Use appropriate software commands to re-activate/re-sync mirror if manual intervention is required.

Reconfigure disk as previously configured. e.g. Part of raid volume set or mounted file-system or raw partition or other. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SPARC_T4_1B/SPARC_T4_1B.html


REFERENCE INFORMATION:
SPARC T4-1B Server Module Service Manual at http://docs.oracle.com/cd/E22735_01/html/E22736/gentextid-6458.html#scrolltoc

Detailed SVM instructions can be found in doc 1006196.1 and also at  http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html.
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions