Solution Type Technical Instruction Sure Solution 1452954.1 : How to replace a faulty DIMM in the Netra CP3260 blade
Need to replace the pair of fault DIMM especially if the vendor is different from the existing DIMMs In this Document
Applies to:Sun Netra CP3260 ATCA Blade Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalBring the awareness of customers and the Field to save unncessary trip of DIMM replacement. FixWhen the fault is diagnosed to a single DIMM onto the Netra CP3260 blade and replacement is needed, please be sure to order a PAIR instead just one single DIMM.
If the new DIMM is from the same vendor of the existing DIMMs, replace the single problematic DIMM. If the new DIMM is from a different vendor of the existing DIMMs, replace the PAIR of DIMM with the SAME vendor (the newly replaced PAIR should have the same vendor if different from the exisiting DIMMs).
To verify the existing DIMM vendor, please use the "showfru" command on one of the following component from the ALOM:
Or one of the following "show" command form ILOM: -> show -level all /SYS/MB/CMP0 -> show -o table -level all /SYS/MB/CMP0
If the DIMMs are from different vendor in the same bank, it could cause the entire channel (CH0/CH1) to be disabled; and only half of the memory size is visible to the blade. This will be a big issue for the cusotmer. References@<NOTE:1346731.1> - Netra CP 3260 Current Product IssuesAttachments This solution has no attachment |
||||||||||||||||
|