Goal
Netra 240, How to Replace the Air Duct and Rear Fan Assembly
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Netra 240 product training is desirable but not required
TASK COMPLEXITY: 0
TIME ESTIMATE: 45 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: Air Duct and Rear Fan Assembly
OBTAIN CUSTOMER ACCEPTANCE
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
The air duct and rear fan assembly contains two fans, F0 and F1. The entire rear fan assembly should be replaced if one of these fans fail.
Removing or Rotating the Air Duct and Rear Fan Assembly
1.Power off the server.
2.Remove the server cover.
3.Open the rotating service module.
4.Ensure that the server is properly grounded.
5.Determine if you want to gain access to the components beneath the air duct and rear fan assembly, or if you want to completely remove the assembly from the server
■If you want to gain access to components beneath the air duct and rear fan assembly, push the tab on the right of the assembly to the rear of the system, then rotate it up and out of the way.
■If you want to completely remove the air duct and rear fan assembly from the server:
a.Push the tab on the right of the assembly to the rear of the assembly and rotate the assembly up.
b. Unplug the two lower cables from the system board.
c. Dislodge the assembly from the rear supports and slide it out of the system.
Installing or Closing the Air Duct and Rear Fan Assembly
1.Slide the air duct and rear fan assembly into position.
2.Plug in the two lower cables from the system board
3.Rotate the assembly back in position and press down to snap the locking tab.
4.Close the rotating service module.
5.Install the server cover.
6.Power on the server.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: Include Air Duct and Rear Fan Assembly location
https://support.oracle.com/handbook_private/Systems/Netra_240/components.html#Fan
https://support.oracle.com/handbook_private/Systems/Netra_240_R/components.html#Fan
ADDITIONAL COMMENTS:
Please refer to the Netra 240 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n240.srvr/817-2699-13/817-2699-13.pdf
Attachments
This solution has no attachment