How to Use a SPARC T3-1B Dongle Cable Adapter:ATR:1444734.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
SPARC T3-1B - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Use a SPARC T3-1B Dongle Cable Adapter
****************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1444734.1
****************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T3-1B training is desirable but not required
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: how to use T3-1B dongle cable adapter
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
N/A
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
No cables are connected to the server module during normal system operation. For setup, testing, or service purposes, you can connect cables directly to the server module by first attaching a dongle cable to the UCP on the front panel of the server module.
Electrical
Caution - Dongle cables are intended for setup, testing, or service purposes and should be removed when not in use. These cables have not been evaluated for electromagnetic compatibility compliance and are not to be used during normal system operation.
You can use the dongle cable that shipped with the modular system chassis or order an optional dongle cable with the server module.
There are two types of dongle cables, with either three or four connectors. Use the three-connector dongle cable (UCP-3) instead of the four-connector version (UCP-4) whenever possible.
Both the UCP-3 and UCP-4 dongle cables provide a USB 2.0 connection (with two connectors) and an HD-15 female connector. The serial connectors differ on the two types of dongle cables:
* The UCP-3 dongle cable has an RJ-45 connector.
* The UCP-4 dongle cable has an RJ-45 connector, but that is not supported on this server module. Instead, use the DB-9 connector provided on the UCP-4. If you need an RJ-45 connection, attach an optional DB-9-to-RJ-45 adapter to the DB-9 connector.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
N/A
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SPARC_T3_1B/SPARC_T3_1B.html
REFERENCE INFORMATION:
SPARC T3-1B Server Module Service Manual at http://docs.oracle.com/cd/E19332-01/E24985/gentextid-5145.html#scrolltoc