Asset ID: |
1-71-1435946.1 |
Update Date: | 2012-05-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1435946.1
:
ODA ( Oracle Database Appliance) : How to Replace a FAILED Shared Storage Disk
Related Items |
- Oracle Database Appliance
|
Related Categories |
- PLA-Support>Sun Systems>x64>Engineered Systems HW>SN-x64: ORA-DATA-APP
|
In this Document
Applies to:
Oracle Database Appliance - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a Failed Shared Storage Disk Drive on an Oracle Database Appliance range of servers.
Fix
DISPATCH INSTRUCTIONS:
Prior to the FSE being dispatched, the EEST/TSC and customer must ensure that the drive is ready to be replaced.
WHAT SKILLS DOES THE ENGINEER NEED:
The engineer must be ODA trained.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 2
PROBLEM OVERVIEW:
Steps to remove a failed hard drive in ODA.
FIELD ENGINEER INSTRUCTIONS:
Identify that you have a failed disk drive
# oakcli show disk
NAME PATH TYPE STATE STATE_DETAILS
pd_00 /dev/sdam HDD ONLINE Good
pd_01 /dev/sdaw HDD ONLINE Good
pd_02 /dev/sdaa HDD ONLINE Good
pd_03 /dev/sdak HDD ONLINE Good
pd_04 /dev/sdan HDD ONLINE Good
pd_05 /dev/sdax HDD ONLINE Good
pd_06 /dev/sdab HDD ONLINE Good
pd_07 /dev/sdal HDD ONLINE Good
pd_08 /dev/sdao HDD ONLINE Good
pd_09 /dev/sdau HDD FAILED DiskRemoved
pd_10 /dev/sdac HDD ONLINE Good
pd_11 /dev/sdai HDD ONLINE Good
pd_12 /dev/sdap HDD ONLINE Good
pd_13 /dev/sdav HDD ONLINE Good
pd_14 /dev/sdad HDD ONLINE Good
pd_15 /dev/sdaj HDD ONLINE Good
pd_16 /dev/sdaq HDD ONLINE Good
pd_17 /dev/sdas HDD ONLINE Good
pd_18 /dev/sdae HDD ONLINE Good
pd_19 /dev/sdag HDD ONLINE Good
pd_20 /dev/sdar SSD ONLINE Good
pd_21 /dev/sdat SSD ONLINE Good
pd_22 /dev/sdaf SSD ONLINE Good
pd_23 /dev/sdah SSD ONLINE Good
The above output shows that the disk in slot 9 has failed.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:
It is expected that the ODA is up and running and the node containing the failed drive is booted and available.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Determine the drive slot location for the replacement drive.
If you removed an existing drive from a slot in the system, you must install the replacement drive in the same slot as the drive that was removed. Drives are physically addressed according to the slot in which they are installed.
Drive Slot Numbers Drive Slot Numbers Drive Slot Numbers Drive Slot Numbers
SSD20 SSD21 SSD22 SSD23
HDD16 HDD17 HDD18 HDD19
HDD12 HDD13 HDD14 HDD15
HDD8 HDD9 HDD10 HDD11
HDD4 HDD5 HDD6 HDD7
HDD0 HDD1 HDD2 HDD3
------------------------------------------------------------------------------------------------------------------------
After insertion of new disk, run the fwupdate command to make sure the replacement disk is successfully seen by the OS.
The fwupdate command should list all of the disks under the DISKS section.
For example:
# fwupdate list disk
==================================================
CONTROLLER
==================================================
ID Manufacturer Model Product Name FW Version BIOS Version XML Support
------------------------------------------------------------------------------------------
c0 Intel 0x3a22 - - - N/A
DISKS
===============
ID Manufacturer Model Chassis Slot Type Media Size (GB) FW Version XML Support
------------------------------------------------------------------------------------------
c0d0 SEAGATE ST95001N - 0 sata HDD 500 SA03 N/A
c0d1 SEAGATE ST95001N - 1 sata HDD 500 SA03 N/A
==================================================
CONTROLLER
==================================================
ID Manufacturer Model Product Name FW Version BIOS Version XML Support
------------------------------------------------------------------------------------------
c1 LSI Logic 0x0072 SGX-SAS6-INT-Z 05.00.29.00 07.05.05.00 N/A
DISKS
===============
ID Manufacturer Model Chassis Slot Type Media Size (GB) FW Version XML Support
------------------------------------------------------------------------------------------
c1d0 SEAGATE ST360057SSUN600G 0 0 sas HDD 600 0A25 N/A
c1d1 SEAGATE ST360057SSUN600G 0 1 sas HDD 600 0A25 N/A
c1d2 SEAGATE ST360057SSUN600G 0 2 sas HDD 600 0A25 N/A
c1d3 SEAGATE ST360057SSUN600G 0 3 sas HDD 600 0A25 N/A
c1d4 SEAGATE ST360057SSUN600G 0 4 sas HDD 600 0A25 N/A
c1d5 SEAGATE ST360057SSUN600G 0 5 sas HDD 600 0A25 N/A
c1d6 SEAGATE ST360057SSUN600G 0 6 sas HDD 600 0A25 N/A
c1d7 SEAGATE ST360057SSUN600G 0 7 sas HDD 600 0A25 N/A
c1d8 SEAGATE ST360057SSUN600G 0 8 sas HDD 600 0A25 N/A
c1d9 SEAGATE ST360057SSUN600G 0 9 sas HDD 600 0A25 N/A << make sure slot 9 is listed
c1d10 SEAGATE ST360057SSUN600G 0 10 sas HDD 600 0A25 N/A
c1d11 SEAGATE ST360057SSUN600G 0 11 sas HDD 600 0A25 N/A
c1d12 SEAGATE ST360057SSUN600G 0 12 sas HDD 600 0A25 N/A
c1d13 SEAGATE ST360057SSUN600G 0 13 sas HDD 600 0A25 N/A
c1d14 SEAGATE ST360057SSUN600G 0 14 sas HDD 600 0A25 N/A
c1d15 SEAGATE ST360057SSUN600G 0 15 sas HDD 600 0A25 N/A
c1d16 SEAGATE ST360057SSUN600G 0 16 sas HDD 600 0A25 N/A
c1d17 SEAGATE ST360057SSUN600G 0 17 sas HDD 600 0A25 N/A
c1d18 SEAGATE ST360057SSUN600G 0 18 sas HDD 600 0A25 N/A
c1d19 SEAGATE ST360057SSUN600G 0 19 sas HDD 600 0A25 N/A
c1d20 STEC ZeusIOPs G3 0 20 sas SSD 73 E125 N/A
c1d21 STEC ZeusIOPs G3 0 21 sas SSD 73 E125 N/A
c1d22 STEC ZeusIOPs G3 0 22 sas SSD 73 E125 N/A
c1d23 STEC ZeusIOPs G3 0 23 sas SSD 73 E125 N/A
==================================================
CONTROLLER
==================================================
ID Manufacturer Model Product Name FW Version BIOS Version XML Support
------------------------------------------------------------------------------------------
c2 LSI Logic 0x0072 SGX-SAS6-INT-Z 05.00.29.00 07.05.05.00 N/A
DISKS
===============
ID Manufacturer Model Chassis Slot Type Media Size (GB) FW Version XML Support
------------------------------------------------------------------------------------------
c2d0 SEAGATE ST360057SSUN600G 0 0 sas HDD 600 0A25 N/A
c2d1 SEAGATE ST360057SSUN600G 0 1 sas HDD 600 0A25 N/A
c2d2 SEAGATE ST360057SSUN600G 0 2 sas HDD 600 0A25 N/A
c2d3 SEAGATE ST360057SSUN600G 0 3 sas HDD 600 0A25 N/A
c2d4 SEAGATE ST360057SSUN600G 0 4 sas HDD 600 0A25 N/A
c2d5 SEAGATE ST360057SSUN600G 0 5 sas HDD 600 0A25 N/A
c2d6 SEAGATE ST360057SSUN600G 0 6 sas HDD 600 0A25 N/A
c2d7 SEAGATE ST360057SSUN600G 0 7 sas HDD 600 0A25 N/A
c2d8 SEAGATE ST360057SSUN600G 0 8 sas HDD 600 0A25 N/A
c2d9 SEAGATE ST360057SSUN600G 0 9 sas HDD 600 0A25 N/A << slot 9 should be listed also
c2d10 SEAGATE ST360057SSUN600G 0 10 sas HDD 600 0A25 N/A
c2d11 SEAGATE ST360057SSUN600G 0 11 sas HDD 600 0A25 N/A
c2d12 SEAGATE ST360057SSUN600G 0 12 sas HDD 600 0A25 N/A
c2d13 SEAGATE ST360057SSUN600G 0 13 sas HDD 600 0A25 N/A
c2d14 SEAGATE ST360057SSUN600G 0 14 sas HDD 600 0A25 N/A
c2d15 SEAGATE ST360057SSUN600G 0 15 sas HDD 600 0A25 N/A
c2d16 SEAGATE ST360057SSUN600G 0 16 sas HDD 600 0A25 N/A
c2d17 SEAGATE ST360057SSUN600G 0 17 sas HDD 600 0A25 N/A
c2d18 SEAGATE ST360057SSUN600G 0 18 sas HDD 600 0A25 N/A
c2d19 SEAGATE ST360057SSUN600G 0 19 sas HDD 600 0A25 N/A
c2d20 STEC ZeusIOPs G3 0 20 sas SSD 73 E125 N/A
c2d21 STEC ZeusIOPs G3 0 21 sas SSD 73 E125 N/A
c2d22 STEC ZeusIOPs G3 0 22 sas SSD 73 E125 N/A
c2d23 STEC ZeusIOPs G3 0 23 sas SSD 73 E125 N/A
Attachments