![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1434045.1 : Sun Storage 7000 Unified Storage System: Verifying the Fabric health to troubleshoot Fibre-Channel connectivity
In this Document
Applies to:Sun ZFS Storage 7120 - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun Storage 7110 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 7210 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 7310 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 7410 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Information in this document applies to any platform. GoalVerifying the Fabric health for Fibre-Channel connectivity of the Unified StorageSolutionThis document will be useful for troubleshooting when transport errors / timeouts / target connectivity issues are seen on the host when it is connected over a fabric to the ZFSSA Unified Storage.Verify SAN configuration and Zoning Setup To ensure HBA's will not see each other, a minimum of one zone per initiator per fabric is needed. Different methodologies of zoning exists, like WWN based zoning and San switch port based zoning. Check for errors logged by the switches. This might require extra logging enabled on switches. This may be useful if link errors are seen.Refer to the following documentation to troubleshoot fabric connectivity issues. <Document: Sun StorageTek[TM] Brocade SAN Switches: Troubleshooting hardware errors external to switch (Doc ID 1020241.1)> <Document: Check zoning configuration to ensure initiator and target pair are properly zoned together. Refer to Technical Instruction: (Doc ID 1020237.1)> <Document: SAN: Troubleshooting Solaris[TM] 10 (not for Solaris[TM] 8 & 9) Fibre Channel (FC) HBA list in "NOT CONNECTED" status. Doc ID (1303745.1)> <Document: SAN: How To Collect and Send Explorer Data to Oracle SAN Support (Doc ID 1273941.1)> <Document: Checking Interconnecting Elements (IEs) in a SAN/Fibre Channel (FC) path (Doc ID 1400156.1)> <Document: Brocade - What logs are required to troubleshoot a Brocade switch? (Doc ID 1003754.1)> <Document: McData - What logs are required to troubleshoot a McData switch? (Doc ID 1015572.1)> <Document: Cisco MDS switch - What logs are required to troubleshoot a Cisco MDS switch? (Doc ID 1016141.1)> <Document: Troubleshooting Fibre Channel HBA Performance (Doc ID 1283727.1)> Attachments This solution has no attachment |
||||||||||||
|