Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1432735.1
Update Date:2012-03-27
Keywords:

Solution Type  Technical Instruction Sure

Solution  1432735.1 :   M4000/M5000/M8000/M9000 Servers: Domain Configuration Considerations  


Related Items
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  




In this Document
  Goal
  Solution
     M4000 / M5000
     Creating a single domain on an M4000
     Creating two domain on an M4000
     
     M8000 / M9000
     M8000/M9000 IO Rules
     References


Applies to:

Sun SPARC Enterprise M5000 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun SPARC Enterprise M9000-64 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun SPARC Enterprise M8000 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun SPARC Enterprise M9000-32 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun SPARC Enterprise M4000 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

Device Considerations and setup steps for Mx000 Servers.

Solution

M4000 / M5000

The below table shows which XSB is used with which device.  When creating 2 domains on a M4000, the XSB 00-0 would be in one domain and XSB 00-1 will have to be used in the other domain to access an external boot device.
XSBCPUMemory BoardI/O
PSB0  ( M4000 / M5000 )
00-0 CPUM#0-CHIP#0MEMB#0Disks 0 & 1, DVD/DAT, GbE, IOU#0-PCI#0, IOU#0-PCI#1, IOU#0-PCI#2
00-1CPUM#0-CHIP#1 MEMB#1IOU#0-PCI#3, IOU#0-PCI#4
00-2 CPUM#1-CHIP#0 MEMB#2 None
00-3 CPUM#1-CHIP#1 MEMB#3 None
PSB1 ( M5000 Only )
01-0 CPUM#2-CHIP#0 MEMB#4 Disks 2 & 3, GbE, IOU#1-PCI#0, IOU#1-PCI#1, IOU#1-PCI#2
01-1 CPUM#2-CHIP#1 MEMB#5 IOU#1-PCI#3, IOU#1-PCI#4
01-2 CPUM#3-CHIP#0 MEMB#6 None
01-3 CPUM#3-CHIP#1 MEMB#7 None

Creating a single domain on an M4000

Setting up Domain 0

XSCF> setupfru -x 1 sb 0
XSCF> showfru sb 0

Device  Location    XSB Mode        Memory Mirror Mode  
sb      00          Uni             no  
          
XSCF> setdcl -d 0 -a 0=00-0
XSCF> addboard -c assign -d 0 00-0

XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y 

XSCF> showdcl -v -d 0
DID LSB XSB Status No-Mem No-IO Float Cfg-policy
00 Powered Off FRU 00 00-0 False False False


XSCF> showboards -a
XSB DID(LSB) Assignment Pwr Conn Conf Test Fault ---- -------- ----------- ---- ---- ---- ------- -------- 00-0 00(00) Assigned y y n Passed Normal

Creating two domain on an M4000

Setting up Domain 0

XSCF> setupfru -x 4 sb 0
XSCF> showfru sb 0
Device Location XSB Mode Memory Mirror Mode
sb 00 Quad no

XSCF> setdcl -d 0 -a 0=00-0
XSCF> setdcl -d 0 -a 1=00-2

XSCF> addboard -c assign -d 0 00-0 00-2
XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y
XSB#00-2 will be assigned to DomainID 0. Continue?[y|n] :y

XSCF> showdcl -v -d 0
DID LSB XSB Status No-Mem No-IO Float Cfg-policy
00 Powered Off FRU
00 00-0 False False False
01 00-2 False False False
...

Setting up Domain 1
XSCF> setdcl -d1 -a 0=00-1
XSCF> setdcl -d1 -a 1=00-3 XSCF> addboard -c assign -d 1 00-1 00-3 XSB#00-1 will be assigned to DomainID 1. Continue?[y|n] :y
XSB#00-3 will be assigned to DomainID 1. Continue?[y|n] :y
XSCF> showdcl -v -d 1
DID LSB XSB Status No-Mem No-IO Float Cfg-policy
01 Powered Off FRU
00 00-1 False False False
01 00-3 False False False
...

XSCF> showboards -a XSB DID(LSB) Assignment Pwr Conn Conf Test Fault ---- -------- ----------- ---- ---- ---- ------- -------- 00-0 00(00) Assigned y y n Passed Normal 00-1 01(00) Assigned y y n Passed Normal 00-2 00(01) Assigned y y n Passed Normal 00-3 01(01) Assigned y y n Passed Normal


M8000 / M9000

XSBCPUMemoryI/O
PSBxx
xx-0 CPUM#0 MEM#00A,B IOU#xx-PCI#0


MEM#01A,B IOU#xx-PCI#1


MEM#02A,B


MEM#03A,B
xx-1 CPUM#1 MEM#10A,B IOU#xx-PCI#2


MEM#11A,B IOU#xx-PCI#3


MEM#12A,B


MEM#13A,B
xx-2 CPUM#2 MEM#20A,B IOU#xx-PCI#4


MEM#21A,B IOU#xx-PCI#5


MEM#22A,B


MEM#23A,B
xx-3 CPUM#3 MEM#30A,B IOU#xx-PCI#6


MEM#31A,B IOU#xx-PCI#7


MEM#32A,B


MEM#33A,B

M8000/M9000 IO Rules

NOTE: In order to control the IOU hard disks the IOU has to be fitted with an IOU/A adaptor card in the following slots
  • Slot 0: control access to DVD/DAT, access to Base IO card's 2 gbe's, and control access to Disks 0 & 1
  • Slot 1:
  • Slot 2: control access to DVD/DAT, access to Base IO card's 2 gbe's
  • Slot 3:
  • Slot 4: control access to DVD/DAT, access to Base IO card's 2 gbe's, and control access to Disks 2 & 3
  • Slot 5:
  • Slot 6: control access to DVD/DAT, access to Base IO card's 2 gbe's
  • Slot 7:
IObox Link cards should only be installed in the odd numbered slots.

References

  • See also 1009927.1 Sun SPARC Enterprise Mx000 (OPL) Servers : Configuration Errors
  • See also 1019113.1 Sun Sparc Enterprise Mx000 (OPL) Servers Memory Configuration Rules



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback