Asset ID: |
1-71-1432735.1 |
Update Date: | 2012-03-27 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1432735.1
:
M4000/M5000/M8000/M9000 Servers: Domain Configuration Considerations
Related Items |
- Sun SPARC Enterprise M9000-64 Server
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M5000 Server
- Sun SPARC Enterprise M4000 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
- .Old GCS Categories>Sun Microsystems>Servers>OPL Servers
|
In this Document
Goal
Solution
M4000 / M5000
Creating a single domain on an M4000
Creating two domain on an M4000
M8000 / M9000
M8000/M9000 IO Rules
References
Applies to:
Sun SPARC Enterprise M5000 Server - Version: Not Applicable and later [Release: N/A and later ] Sun SPARC Enterprise M9000-64 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M8000 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M9000-32 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M4000 Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform.
Goal
Device Considerations and setup steps for Mx000 Servers.
Solution
M4000 / M5000
The below table shows which XSB is used with which device. When creating 2 domains on a M4000, the XSB 00-0 would be in one domain and XSB 00-1 will have to be used in the other domain to access an external boot device.
XSB | CPU | Memory Board | I/O |
PSB0 ( M4000 / M5000 )
|
00-0 | CPUM#0-CHIP#0 | MEMB#0 | Disks 0 & 1, DVD/DAT, GbE, IOU#0-PCI#0, IOU#0-PCI#1, IOU#0-PCI#2 |
00-1 | CPUM#0-CHIP#1 | MEMB#1 | IOU#0-PCI#3, IOU#0-PCI#4 |
00-2 | CPUM#1-CHIP#0 | MEMB#2 | None |
00-3 | CPUM#1-CHIP#1 | MEMB#3 | None |
PSB1 ( M5000 Only )
|
01-0 | CPUM#2-CHIP#0 | MEMB#4 | Disks 2 & 3, GbE, IOU#1-PCI#0, IOU#1-PCI#1, IOU#1-PCI#2 |
01-1 | CPUM#2-CHIP#1 | MEMB#5 | IOU#1-PCI#3, IOU#1-PCI#4 |
01-2 | CPUM#3-CHIP#0 | MEMB#6 | None |
01-3 | CPUM#3-CHIP#1 | MEMB#7 | None |
Creating a single domain on an M4000
Setting up Domain 0
XSCF> setupfru -x 1 sb 0
XSCF> showfru sb 0
Device Location XSB Mode Memory Mirror Mode
sb 00 Uni no
XSCF> setdcl -d 0 -a 0=00-0
XSCF> addboard -c assign -d 0 00-0
XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y
XSCF> showdcl -v -d 0 DID LSB XSB Status No-Mem No-IO Float Cfg-policy 00 Powered Off FRU
00 00-0 False False False
XSCF> showboards -a XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-0 00(00) Assigned y y n Passed Normal
Creating two domain on an M4000
Setting up Domain 0
XSCF> setupfru -x 4 sb 0 XSCF> showfru sb 0 Device Location XSB Mode Memory Mirror Mode sb 00 Quad no
XSCF> setdcl -d 0 -a 0=00-0 XSCF> setdcl -d 0 -a 1=00-2
XSCF> addboard -c assign -d 0 00-0 00-2 XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y XSB#00-2 will be assigned to DomainID 0. Continue?[y|n] :y
XSCF> showdcl -v -d 0 DID LSB XSB Status No-Mem No-IO Float Cfg-policy 00 Powered Off FRU 00 00-0 False False False 01 00-2 False False False ...
Setting up Domain 1
XSCF> setdcl -d1 -a 0=00-1 XSCF> setdcl -d1 -a 1=00-3
XSCF> addboard -c assign -d 1 00-1 00-3
XSB#00-1 will be assigned to DomainID 1. Continue?[y|n] :y XSB#00-3 will be assigned to DomainID 1. Continue?[y|n] :y
XSCF> showdcl -v -d 1 DID LSB XSB Status No-Mem No-IO Float Cfg-policy 01 Powered Off FRU 00 00-1 False False False 01 00-3 False False False ...
XSCF> showboards -a
XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-0 00(00) Assigned y y n Passed Normal
00-1 01(00) Assigned y y n Passed Normal
00-2 00(01) Assigned y y n Passed Normal
00-3 01(01) Assigned y y n Passed Normal
M8000 / M9000
XSB | CPU | Memory | I/O |
PSBxx |
xx-0 | CPUM#0 | MEM#00A,B | IOU#xx-PCI#0 |
|
| MEM#01A,B | IOU#xx-PCI#1 |
|
| MEM#02A,B |
|
|
| MEM#03A,B |
|
xx-1 | CPUM#1 | MEM#10A,B | IOU#xx-PCI#2 |
|
| MEM#11A,B | IOU#xx-PCI#3 |
|
| MEM#12A,B |
|
|
| MEM#13A,B |
|
xx-2 | CPUM#2 | MEM#20A,B | IOU#xx-PCI#4 |
|
| MEM#21A,B | IOU#xx-PCI#5 |
|
| MEM#22A,B |
|
|
| MEM#23A,B |
|
xx-3 | CPUM#3 | MEM#30A,B | IOU#xx-PCI#6 |
|
| MEM#31A,B | IOU#xx-PCI#7 |
|
| MEM#32A,B |
|
|
| MEM#33A,B |
|
M8000/M9000 IO Rules
NOTE: In order to control the IOU hard disks the IOU has to be fitted with an IOU/A adaptor card in the following slots
- Slot 0: control access to DVD/DAT, access to Base IO card's 2 gbe's, and control access to Disks 0 & 1
- Slot 1:
- Slot 2: control access to DVD/DAT, access to Base IO card's 2 gbe's
- Slot 3:
- Slot 4: control access to DVD/DAT, access to Base IO card's 2 gbe's, and control access to Disks 2 & 3
- Slot 5:
- Slot 6: control access to DVD/DAT, access to Base IO card's 2 gbe's
- Slot 7:
IObox Link cards should only be installed in the odd numbered slots.
References
- See also 1009927.1 Sun SPARC Enterprise Mx000 (OPL) Servers : Configuration Errors
- See also 1019113.1 Sun Sparc Enterprise Mx000 (OPL) Servers Memory Configuration Rules
Attachments