![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1414603.1 : How to replace Rear Fan Module on a Sun Blade 6048 Modular System:ATR:1414603.1:0
In this Document
Applies to:Sun Blade 6048 System - Version: Not ApplicableInformation in this document applies to any platform. GoalReplace Rear Fan Module on a Sun Blade 6048 Modular SystemSolutionDISPATCH INSTRUCTIONS- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED: Basic Sun hardware FE skills, familiarity or training for Sun Blade 6048 platform. - TIME ESTIMATE: 15 minutes - TASK COMPLEXITY: 0 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: - PROBLEM OVERVIEW: How to replace Rear Fan Module on a Sun Blade 6048 Modular System - WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: You will need to replace a rear fan module if the module fails. You can remove and replace a rear fan from a powered-off system or from a powered-on system using a hot-swap procedure. - WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE: How to remove a Rear Fan Module1. In the rear of the chassis, locate the fan module that you want to remove.2. Press and hold the green button on the fan handle. 3. Pull out the rear fan module in a smooth motion until it is free from the chassis. How to install a Rear Fan Module1. In the back of the system chassis, locate a vacant fan module slot.2. Using both hands, align the fan module with the vacant slot. Make sure that the green button on the handle of the fan module is at the top of the fan. 3. Slide the fan module into the vacant slot until the front panel meets the chassis. After you install the rear fan module, the chassis management module (CMM) will automatically detect the new module. OBTAIN CUSTOMER ACCEPTANCE - WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: PARTS NOTE: REFERENCE INFORMATION: Sun Blade 6048 Server Service Manual https://docs.oracle.com/cd/E19926-01/ Attachments This solution has no attachment |
||||||||||||
|