Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1413690.1
Update Date:2012-03-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1413690.1 :   How to Replace a Front Fan Module (AC) on a Sun Netra 6000 Modular System:ATR:1413690.1:0  


Related Items
  • Sun Netra 6000 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
  Goal
  Solution
     How to remove a Front Fan Module
     How to install a Front Fan Module


Applies to:

Sun Netra 6000 System - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

Replace a Front Fan Module (AC) on a Sun Netra 6000 Modular System

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Basic Sun hardware FE skills, familiarity or training for Sun Blade 6000 platform.
- TIME ESTIMATE: 15 min
- TASK COMPLEXITY: 0 = CRU replacement

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW:
How to Replace a Front Fan Module (AC) on a Sun Netra 6000 Modular System

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
A front fan module is located within each of the power supply modules, so you must remove the power supply associated with the fan module before replacing the module.

The Power Supply can be removed and the Fan Modules replaced from a powered-off system or from a powered-on system using a hot-swap procedure.

- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:

How to remove a Front Fan Module


Note - You must replace the power supply that you removed within one minute in order to ensure proper system operation.

1. In the front of the chassis, locate the power supply to be removed.
The amber Fan Service LED on the Power Supply will be ON.
2. Press and hold the green button on top of the power supply handle frame.
Rotate the power supply handle down and away from the power supply.
Pull the power supply out of the system far enough to access the fan.
You do not need to remove it completely from the system.

Caution - The fan continues spinning for a moment after the power supply is disconnected. Be careful not to insert a finger or other object into the fan while it is still spinning.

3. Press together the two latches on top of the fan module and pull the module upward and out of the power supply chassis.

How to install a Front Fan Module

1. Insert the new fan module into the front of the power supply.
2. In a smooth motion, slide the power supply into the power supply slot until the unit engages with the internal connectors.
3. Push the power supply handle back toward the power supply until it clicks into place.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:
Sun Netra 6000 Modular System Service Manual https://docs.oracle.com/cd/E19945-01/