![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1408348.1 : How to Replace a Sun ZFS Unified Storage Appliance Memory DIMM:ATR:1408348.1:0
Applies to:Sun ZFS Storage 7320 - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun Storage 7310 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun ZFS Storage 7120 - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun ZFS Storage 7320 - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun ZFS Storage 7420 - Version: Not Applicable to Not Applicable [Release: N/A to N/A] 7000 Appliance OS (Fishworks) GoalReplace DIMM in a Unified Storage systemSolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER/ADMINISTRATOR NEED: Knowledge of appliance hardware TIME ESTIMATE: 30 mins TASK COMPLEXITY: 0 PROBLEM OVERVIEW What: Replace faulty DIMM Where: DIMM [SR owner to specify], confirm location with BUI: Maintenance - Hardware - show details - DIMM Why : DIMM diagnosed faulty REPLACEMENT INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY: * Shut down appliance * Disconnect power cords WHAT ACTION DOES THE ENGINEER/ADMINISTRATOR NEED TO TAKE: 1 Take antistatic precautions 2 Remove system from rack 3 Remove top cover - press release button, slide slightly to rear before removing * If servicing a 7410, lift the air duct to replace DIMMs on the mezzanine board, or remove the mezzanine tray to replace DIMMs on the motherboard 4 Remove DIMM * To help identify faulty DIMM, press Fault Remind button on motherboard, a corresponding amber LED is lit * If servicing a 7420, lift memory riser that hosts faulted DIMM straight up to remove it from motherboard * Rotate both DIMM slot ejectors outward to partially eject the DIMM * Lift DIMM straight up to remove 5 Install DIMM * DIMMs must be installed in matched pairs in 7x10 and 7420 systems: 7x10 paired slots are 0/1, 2/3, 4/5, and 6/7. Memory sockets are colored black or white to indicate which slots are paired. Each pair of DIMMs must be identical (same manufacturer/size/speed) 7420 paired slots are D0/D4 (blue slots), D2/D6 (white slots), D1/D5 (black slots) and D3/D7 (green slots). DIMMs populated in same-colored slots must have same part number * Ensure that ejector tabs are fully open * Align notch in the DIMM with the key in connector * Push DIMM into connector until ejector tabs lock DIMM in place * On 7420 push memory riser module back into memory riser slot until it locks in place 6 Return system to operational state * Place top cover on chassis so that it overhangs rear of the unit slightly. Slide forward until it seats * Close fan cover and engage fan cover latches. Cover must be completely closed for the system to power on * Reinstall appliance back in original rack location * Reconnect all cables * Verify standby power is on - Power/OK LED flashes on front panel about 2 minutes after power cords are plugged in * Use a pen to press the recessed Power button on the front panel. The Power/OK LED will stay solidly lit. SSH to the Service Processor and check appliance power state show /SYS power_state If off start system start /SYS OBTAIN CUSTOMER ACCEPTANCE Confirm appliance is in normal state. Check both BUI and client data access WHAT ACTION DOES THE ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Confirm there are no faults reported in appliance BUI Maintenance - Problems ("Mark Repaired" any prior related DIMM faults) Should an error return for the same DIMM, reseat the DIMM and monitor the appliance for further errors PARTS NOTE: Check System Handbook for correct part number ReferencesCustomer Service Manuals: http://www.oracle.com/technetwork/documentation/oracle-unified-ss-193371.htmlSystem Handbook: https://support.oracle.com/handbook_private/ Attachments This solution has no attachment |
||||||||||||
|