Solution Type Technical Instruction Sure Solution 1402253.1 : Sun Storage 7000 Unified Storage System: Useful ipmitool commands for data collection
In this Document
Applies to:Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 7110 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7210 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] 7000 Appliance OS (Fishworks) GoalProvide a list of useful ipmitool commands for data collection about the Service Processor (SP) on a Sun Storage 7000 Unified Storage System Fix1.- To get help options, interfaces commands # ipmitool -h or # ipmitool <cmd> help
# ipmitool -I lan -H <ILOM IP address> -U root chassis power status 3.- Collect the output from the following ipmitool commands to help further troubleshoot. Run the following against the ILOM: ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> bmc info
show -l all /SYS