Asset ID: |
1-71-1400578.1 |
Update Date: | 2012-02-22 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1400578.1
:
Sun Storage 7000 Unified Storage System: How to collect SP/ILOM diagnostic data
Related Items |
- Sun Storage 7410 Unified Storage System
- Sun Storage 7310 Unified Storage System
- Sun ZFS Storage 7120
- Sun Storage 7110 Unified Storage System
- Sun ZFS Storage 7420
- Sun ZFS Storage 7320
- Sun Storage 7210 Unified Storage System
|
Related Categories |
- PLA-Support>Sun Systems>DISK>NAS>SN-DK: 7xxx NAS
- .Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
|
Applies to:
Sun Storage 7110 Unified Storage System - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Sun ZFS Storage 7120 - Version: Not Applicable to Not Applicable [Release: N/A to N/A]
Sun Storage 7410 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A]
Sun ZFS Storage 7420 - Version: Not Applicable to Not Applicable [Release: N/A to N/A]
Sun Storage 7310 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A]
7000 Appliance OS (Fishworks)
Goal
The purpose of this document is to assist in collecting data from the Service Processor (SP) for further troubleshooting by Oracle support.
Solution
First step is to determine the Service Processor ( SP ) IP address
- go to Web BUI: Maintenance
- go to Hardware
- select the controller chassis, the Head
- go to "Show Details"
- go to "SP"
From there the IP address assigned to the ILOM or Service Processor can be obtained.
From the CLI you can use the following command line after logging into the Sun Storage 7000 Unified Storage System
ZFS700:> maintenance hardware select chassis-000 select sp ls
Properties:
macaddr = 0:14:4f:f7:dd:70
ipaddr_src = dhcp
ipaddr = 192.168.1.10
subnet = 255.255.255.0
gateway = 192.168.1.1
With the IP address, you are now ready to use the following documents:
- Sun Storage 7000 Unified Storage System: How to collect data from SP (Doc ID 1395915.1)
- shows two method can be used for collect data from the SP.
- SP CLI or with ipmitool.
By using the SP CLI or with ipmitool.
Below are the commands to be run depends on which method are used.
- Collecting snapshot on ILOM 3.x and later platforms (Doc ID 1020204.1)
- The utility collects log files, runs various commands and collects their output, and sends the data collection as a zip file to a user defined location.
- Sun Storage 7000 Unified Storage System: Service Processor (SP) Issues (Doc ID 1168273.1)
- Oracle Integrated Lights Out Manager (ILOM) 3.0 HTML Documentation Collection
- ILOM Service Processor sunservice commands for Sun Fire[TM] X4100 Server (applies to SFX4200/SFX4500/SFX4600 also) (Doc ID 1004226.1)
- collectHostStatus.sh' is a utility in the ILOM Service Processor (SP) firmware .
is used to collect host status information for analysis by developers, when a server is malfunctioning. IPMI sensor information, IPMI sel log history, and optionally detailed server cpu status information are collected.
- Tools: ILOM SnapshotMiner
References
<NOTE:1324444.1> - Sun Storage 7000 Unified Storage System: Fan Troubleshooting
<NOTE:1267544.1> - Older versions of the Service Processor firmware on Sun Storage 7110, 7210, 7310 and 7410 can leak memory.
<BUG:6925325> - ELWOOD (2U) CHASSIS FAN BOARD INTERMITTENTS CAUSING FANS TO "DISSAPPEAR"& TACHOMETER READING ERRORS
<NOTE:1400710.1> - Sun ZFS Storage Appliance: How to perform SP reset from BUI/CLI
Attachments