Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1398633.1
Update Date:2012-05-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1398633.1 :   Sun Storage 7000 Unified Storage System: How to check iSNS/RADIUS settings on ZFSSA  


Related Items
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7720 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun ZFS Storage 7320
  •  
  • Sun ZFS Storage 7420
  •  
  • Sun Storage 7210 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>NAS>SN-DK: 7xxx NAS
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  




In this Document
Goal
Fix
 Identifying if iSNS Discovery Is Set up Correctly on the ZFSSA:
 Identifying if ZFSSA is Set Up Correctly for RADIUS Authentication:
References


Applies to:

Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 7720 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 7210 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
Sun ZFS Storage 7320 - Version Not Applicable to Not Applicable [Release N/A]
Sun ZFS Storage 7420 - Version Not Applicable to Not Applicable [Release N/A]
7000 Appliance OS (Fishworks)

Goal

This document describes how to obtain information about iSNS and RADIUS settings on Oracle ZFS Storage Appliance (ZFSSA.)

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - 7000 Series ZFS Appliances

Fix

Identifying if iSNS Discovery Is Set up Correctly on the ZFSSA:

This section is valid ONLY WHEN you are using iSNS as a discovery method of iSCSI devices from the host.

ZFSSA must be registered if you are using iSNS as a discovery method for initiator to find iSCSI IQNs.  The following command shows you the IP address or host name of iSNS server. If you are using the host name, make sure it can be resolved to it's IP address correctly. (The following example DOES NOT have any of iSNS properties.)

oratkyar1:> configuration services iscsi
oratkyar1:configuration services iscsi> show
Properties:
<status> = online
isns = (unset)
isnsserver = (unset)

radiussecret = (unset)
radiusserver = (unset)

Identifying if ZFSSA is Set Up Correctly for RADIUS Authentication:

This section is valid ONLY WHEN you plan to use RADIUS as a means of iSCSI authentication. You need to consult with the respective product documentation to set up a RADIUS server.
The following command shows you the IP address or host name of the RADIUS server and the RADIUS secret. If you are using the host name for RADIUS server, make sure it can be resolved to it's IP address correctly. (The following example DOES NOT have any of RADIUS properties.)

oratkyar1:> configuration services iscsi
oratkyar1:configuration services iscsi> show
Properties:
<status> = online
isns = (unset)
isnsserver = (unset)
radiussecret = (unset)
radiusserver = (unset)


Return to <Document 1398581.1> Sun Storage 7000 Unified Storage System: How to Troubleshoot iSCSI Problems.

References

<NOTE:1398581.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot iSCSI Problems