Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1395320.1
Update Date:2012-05-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1395320.1 :   Sun Storage 7000 Unified Storage System: How to identify target IQN on ZFSSA  


Related Items
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7720 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun ZFS Storage 7320
  •  
  • Sun ZFS Storage 7420
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>NAS>SN-DK: 7xxx NAS
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  




In this Document
Goal
Fix
 What is the Target IQN?
 Identify the target IQN:
References


Applies to:

Sun ZFS Storage 7320 - Version Not Applicable to Not Applicable [Release N/A]
Sun ZFS Storage 7420 - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 7110 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
Sun ZFS Storage 7120 - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
7000 Appliance OS (Fishworks)

Goal

This document explains steps to identify the target IQN on a ZFS Storage Appliance (ZFFSA.)

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - 7000 Series ZFS Appliances

Fix

What is the Target IQN?

Target IQNs are iSCSI Qualified Names for the given target LUN on the Oracle ZFS Storage Appliance.  The target IQN will be used to point to the LUN from the initiator host.

Identify the target IQN:

Follow the steps below to identify target IQNs.

1. Log on to the appliance CLI

solaris$ ssh -l root 192.168.150.21
Password:
oratkyar1:>


2. Run following commands to verify target IQNs.

oratkyar1:> configuration san
oratkyar1:configuration san> targets
oratkyar1:configuration san targets> iscsi
oratkyar1:configuration san targets iscsi> show
Targets:

TARGET ALIAS
target-000 iscsitgt1
|
+-> IQN
iqn.1986-03.com.sun:02:a12800dd-0262-48a7-9482-ef0c95ca0c4e


Children:
groups => Manage groups

oratkyar1:configuration san targets iscsi>


Return to <Document 139858.1> Sun Storage 7000 Unified Storage System: How to Troubleshoot iSCSI Problems.

References

<NOTE:1398581.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot iSCSI Problems