![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1394599.1 : How to Replace the Front Fan Modules on a Sun Blade 6000 system:ATR:1394599.1:0
In this Document
Applies to:Sun Blade 6000 System - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. GoalReplace the Front Fan Modules on a Sun Blade 6000 systemSolutionDISPATCH INSTRUCTIONS- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED: Basic Sun hardware FE skills, familiarity or training for Sun Blade 6000 platform. - TIME ESTIMATE: 15 minutes - TASK COMPLEXITY: 0 = CRU replacement FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: - PROBLEM OVERVIEW: How to Replace the Front Fan Modules in a Sun Blade 6000 system. - WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: A front fan module is located within each of the power supply modules, so you must remove the power supply associated with the fan module before replacing the module. The Power Supply can be removed and the Fan Modules replaced from a powered-off system or from a powered-on system using a hot-swap procedure. - WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE: How to remove a Front Fan ModuleNote - You must replace the power supply that you removed within one minute in order to ensure proper system operation. 1. In the front of the chassis, locate the power supply to be removed. The amber Fan Service LED on the Power Supply will be ON. 2. Press and hold the green button on top of the power supply handle frame. Rotate the power supply handle down and away from the power supply. Pull the power supply out of the system far enough to access the fan. You do not need to remove it completely from the system. Caution - The fan continues spinning for a moment after the power supply is disconnected. Be careful not to insert a finger or other object into the fan while it is still spinning. 3. With one hand, squeeze together the two latches on top of the fan module and pull the module upward. 4. Grasp the module with the other hand as soon as possible. How to install a Front Fan Module1. Insert the new fan module into the front of the power supply.2. In a smooth motion, slide the power supply into the power supply slot until the unit engages with the internal connectors. 3. Push the power supply handle back toward the power supply until it clicks into place. OBTAIN CUSTOMER ACCEPTANCE - WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: PARTS NOTE: REFERENCE INFORMATION: Sun Blade 6000 Server Service Manual https://docs.oracle.com/cd/E19938-01/ Attachments This solution has no attachment |
||||||||||||
|