Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1392936.1
Update Date:2012-10-02
Keywords:

Solution Type  Technical Instruction Sure

Solution  1392936.1 :   CAM - How to Remove and Replace Single/Simplex 2500 RAID Controller:ATR:1392936.1:0  


Related Items
  • Sun Storage 2510 Array
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage 2530 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Storage 2530 Array - Version Not Applicable and later
Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 2540 Array - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a Single/SIMPLEX 2500 RAID Controller

Fix

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Common Array Manager
- TIME ESTIMATE:40 minutes
- TASK COMPLEXITY:0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW:
25x0 Simplex Controller needs to be replaced.

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
1.  Stop all I/O before starting.

2.  Do not power off the array. 

- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:

- Make sure the array is registered in CAM before proceeding with the replacement.
- Do not remove the array from CAM until the replacement has been completed.

 

1.  Log into Common Array Manager

2.  Launch the Service Advisor.

3.  Follow the steps for Controller Removal/Replacement.

4.  If CAM can not contact the array after being powered on for 2 or more minutes, proceed to step 5.

5.  Verify that your CAM version is 6.2.0 or higher.

6.  Verify the controller IP address is correct, this requires a serial connection to the controller.  Reference: Sun StorageTek 2500 Series Array Hardware Installation Guide

7.  Run the following csmservice command. The correct controller firmware will be loaded, the array will reboot.

Typical Command Locations: 
Solaris: /opt/SUNWsefms/bin
Windows: c:\Program Files\Sun\Common Array Manager\Component\fms\bin OR c:\Program Files (x86)\Sun\Common Array Manager\Component\fms\bin 
Linux: /opt/sun/cam/private/fms/bin
 csmservice -i -a <array-name> -Z UNLOCK -w 
                              OR
 csmservice -i -a <array-name> -f -Z UNLOCK -w

 

 

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:
Array Documentation [Release Notes]  at http://docs.oracle.com/cd/E19508-01/820-6247-13/820-6247-13.pdf
Array Documentation  at http://docs.oracle.com/cd/E19508-01/index.html


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback