Applies to:Sun Storage 2530 Array - Version Not Applicable and laterSun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2540 Array - Version Not Applicable and later Information in this document applies to any platform. GoalHow to Remove and Replace a Single/SIMPLEX 2500 RAID Controller FixDISPATCH INSTRUCTIONS 2. Do not power off the array. - Make sure the array is registered in CAM before proceeding with the replacement.
- Do not remove the array from CAM until the replacement has been completed.
1. Log into Common Array Manager 2. Launch the Service Advisor. 3. Follow the steps for Controller Removal/Replacement. 4. If CAM can not contact the array after being powered on for 2 or more minutes, proceed to step 5. 5. Verify that your CAM version is 6.2.0 or higher. 6. Verify the controller IP address is correct, this requires a serial connection to the controller. Reference: Sun StorageTek 2500 Series Array Hardware Installation Guide 7. Run the following csmservice command. The correct controller firmware will be loaded, the array will reboot. Typical Command Locations:
Solaris: /opt/SUNWsefms/bin Windows: c:\Program Files\Sun\Common Array Manager\Component\fms\bin OR c:\Program Files (x86)\Sun\Common Array Manager\Component\fms\bin Linux: /opt/sun/cam/private/fms/bin