Solution Type Technical Instruction Sure Solution 1378598.1 : 8Gb Dual FC HBA PCIe (Metis) correctable errors on Blade servers caused by revision 01 modules - How to determine that PEM is revision 01 from Linux O/S commands.
Oracle Confidential (PARTNER). Do not distribute to customers Reason: Same as Doc ID 1303679.1 Created from <SR 3-3237653191>
Applies to:Sun Fire X4800 M2 - Version: Not ApplicableSun Fire X4800 Server - Version: Not Applicable and later [Release: N/A and later] Sun Blade 6000 System - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalProvide a method of determining a 371-4522-01 module from Linux O/S on X86/X64 "Blade server" architecture ie SB 6000 and X4800 (M2)Solution1) Run command lspciThere are 7 entries associated with the 371-4522 module, for example: 0d:00.0 PCI bridge: Integrated Device Technology, Inc. PES16T4A/4T4G2 PCI Express Gen2 Switch (rev 02) 0e:02.0 PCI bridge: Integrated Device Technology, Inc. PES16T4A/4T4G2 PCI Express Gen2 Switch (rev 02) 0e:03.0 PCI bridge: Integrated Device Technology, Inc. PES16T4A/4T4G2 PCI Express Gen2 Switch (rev 02) 0f:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02) 0f:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02) 10:00.0 Ethernet controller: Intel Corporation 82571EB Gigabit Ethernet Controller (rev 06) 10:00.1 Ethernet controller: Intel Corporation 82571EB Gigabit Ethernet Controller (rev 06) 2) Select the first entry for the IDT switch and note the bus, device function value In the above example this is 0d:00.0 3) Run the following command lspci -vv -s bus:device:function | grep LnkCtl2 In the above example this is lspci -vv -s 0d:00.0 | grep LnkCtl2 4) On a Rev 1 module the output is LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB On a Rev 2 module the output is LnkCtl2: Target Link Speed: 2.5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB 5) Note as per document <Document: 1303679.1> 8GB Dual HBA PCIe (Metis) correctable errors on Blade servers. This should be confirmed by physically checking the card. This document also explains the reason for the speed difference. References<NOTE:1303679.1> - 8Gb Dual FC HBA PCIe (Metis) correctable errors on Blade servers.Attachments This solution has no attachment |
||||||||||||
|