Solution Type  Technical Instruction Sure

Solution  1378598.1 :   8Gb Dual FC HBA PCIe (Metis) correctable errors on Blade servers caused by revision 01 modules - How to determine that PEM is revision 01 from Linux O/S commands.  


Related Items
  • Sun Blade 6000 System
  •  
  • Sun Server X2-8
  •  
  • Sun Fire X4800 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Blades>SN-x64: BLADE
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>x64 Servers
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Blade Servers
  •  




Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Same as Doc ID 1303679.1

Created from <SR 3-3237653191>

Applies to:

Sun Fire X4800 M2 - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire X4800 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Blade 6000 System - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

Provide a method of determining a 371-4522-01 module from Linux O/S on X86/X64 "Blade server" architecture ie SB 6000 and X4800 (M2)

Solution

1) Run command lspci

 There are 7 entries associated with the 371-4522 module, for example:

0d:00.0 PCI bridge: Integrated Device Technology, Inc. PES16T4A/4T4G2 PCI Express Gen2 Switch (rev 02)
0e:02.0 PCI bridge: Integrated Device Technology, Inc. PES16T4A/4T4G2 PCI Express Gen2 Switch (rev 02)
0e:03.0 PCI bridge: Integrated Device Technology, Inc. PES16T4A/4T4G2 PCI Express Gen2 Switch (rev 02)
0f:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02)
0f:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02)
10:00.0 Ethernet controller: Intel Corporation 82571EB Gigabit Ethernet Controller (rev 06)
10:00.1 Ethernet controller: Intel Corporation 82571EB Gigabit Ethernet Controller (rev 06)


2) Select the first entry for the IDT switch and note the bus, device function value
In the above example this is 0d:00.0

3) Run the following command lspci -vv -s bus:device:function | grep LnkCtl2

In the above example this is

lspci -vv -s 0d:00.0 | grep LnkCtl2


4) On a Rev 1 module the output is

LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB

On a Rev 2 module the output is

LnkCtl2: Target Link Speed: 2.5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB


5) Note as per document <Document: 1303679.1>

8GB Dual HBA PCIe (Metis) correctable errors on Blade servers.
This should be confirmed by physically checking the card.
This document also explains the reason for the speed difference.