Asset ID: |
1-71-1377062.1 |
Update Date: | 2012-09-28 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1377062.1
:
How To Remove And Replace Clustron Card in a Sun ZFS Unified Storage Appliance Cluster:ATR:1378943.1:1
Related Items |
- Sun Storage 7410 Unified Storage System
- Sun ZFS Storage 7320
- Sun Storage 7310 Unified Storage System
- Sun ZFS Storage 7420
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
|
Applies to:
Sun Storage 7410 Unified Storage System - Version Not Applicable and later
Sun ZFS Storage 7320 - Version Not Applicable and later
Sun ZFS Storage 7420 - Version Not Applicable and later
Sun Storage 7310 Unified Storage System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
To be able to remove and replace a faulty Clustron Card in a Sun ZFS Unified Storage Appliance
Fix
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE CUSTOMER NEED: Experience with Sun ZFS Unified Storage Appliance
- TIME ESTIMATE: 45 minutes
- TASK COMPLEXITY: 1
- PROBLEM OVERVIEW
What: The Clustron card
Where: Chassis S/N: , Slot No. of the card/device to be inserted here by SR owner
Why : The Clustron card has been reported failed or faulted by the appliance.
REPLACEMENT INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
*Please gather and note down specific PCI replacement procedure for the model of the ZFS Unified Storage you are working on before powering off head, or use the 2nd cluster node's "Online help" while this node is powered off.
*Please see "References section" at the bottom of this document for online help links so an offline copy can be saved of the relevant procedure.
*The applaince head must be powered off for this task. The customer may have shut the node down but power may still be applied so check that it is safe to power off.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE:
1. Locate the Clustron Card.
2. Take ESD Precautions.
3. Check the Clustron Card part number for the appropriate system in the System Handbook and re-confirm. Note that the part number is different for SAS1 and SAS2 systems.
4. Take note of order of Clustron cables ( Label each cable if needed to ensure they are cabled correctly after replacement ).
5. Replace the Clustron as per instructions in the "Online Help Guide" under 'Maintenance - Hardware - PCI cards and Risers' ( for the specific platform ).
6. Reconnect Clustron cables in original locations.
7. Verify the replacement by powering on and checking the NAS head/node rejoins the cluster ( customer may have to confirm this)
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Confirm there are no faults reported in the appliance BUI and Cluster is rejoined. Mark Repaired" any prior faults related to Clustron card if required
PARTS NOTE:
Consult System handbook for appropriate model.
Attachments
This solution has no attachment