Asset ID: |
1-71-1373889.1 |
Update Date: | 2012-05-16 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1373889.1
:
CRU Replacement of Power Supply Module in C4 Library:ATR:1373889.1:0
Related Items |
- Sun Storage C4 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
|
In this Document
Applies to:
Sun Storage C4 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.
Checked for relevance on 16-May-2012.
Goal
C4 - CRU Replacement of Power Supply Module in C4 Library.
C4 Redundant Power Supply 380-1391
Fix
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Familiar with C4 Tape Library.
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW:
Power Supply is defective and requires replacement.
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
Stop all work to C4 Library and tape drives. Take C4 and drives offline from OS and software application. Power off the C4 library.
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:
Refer to the C4/Quantum PX500 Service Manual for complete instruction on replacing the Power Supply Module.
http://download-adc.oracle.com/archive/cd_ns/E21109_01/CRCM2216/CRCM2216.pdf
To remove a power supply:
1. Determine which power supply is to be replaced, and turn off its power switch.
2. Loosen the captive screw at the top right of the power supply using a flat blade screwdriver.
3. Pull on the power supply handle to remove the power supply from the chassis (see figure 87).
4. Slide the replacement power supply into the power supply bay and tighten the captive screw.
5. Turn on the power supply.
The power supply replacement is complete.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Power C4 library back on. Bring online to Operating System and Software Application.
PARTS NOTE:
C4 Redundant Power Supply 380-1391
REFERENCE INFORMATION:
C4/Quantum PX500 Service Manual
http://download-adc.oracle.com/archive/cd_ns/E21109_01/CRCM2216/CRCM2216.pdf
Attachments
This solution has no attachment