Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1373776.1
Update Date:2012-04-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1373776.1 :   CRU Replacement of Power Supply in SL48 Library:ATR:1373776.1:0  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun StorageTek SL48 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.

Goal

SL48 - CRU Replacement of Power Supply in SL48 Library.

SL48 Sun Chassis w/o Tape Drive              380-1567

Fix

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Familiar with SL48 library.

- TIME ESTIMATE: 30 minutes

- TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW:
Power supply is defective in the SL48 library and requires replacement.

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
All work to the SL48 library and tapes drives should be stopped.  Library and drives should be placed offline from the Operating System and Software Application.

- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:
Refer to the SL24/SL48 User and Service Guide for complete instructions on replacing the SL48 power supply.
http://download.oracle.com/docs/cd/E25510_01/en/875-4225-11/875-4225-11.pdf

This process applies to the SL48 only. A redundant power supply can be replaced without powering off the Library.
In this process you will:
• Power off the Library, if necessary, and unplug the power cord. (Only Libraries with a single power supply.)
• Remove the old power supply.
• Install the new power supply.
• Verify the replacement.

CAUTION:
Parts can be damaged by electrostatic discharge. Keep parts in electrostatic containers until needed. Ensure that you are properly grounded when touching static‐sensitive components.

To replace a power supply:
1. If the Library only has one power supply, power off the Library from the front panel, if possible, and
    remove the AC power cord. Otherwise, just remove the AC power cord from the power supply to be
    replaced.
2. Loosen the three captive thumbscrews on the power supply. Grasp a thumbscrew stem on each side of
    the power supply and while supporting the bottom, pull the power supply out of the Library, as shown in
    Figure 107).
3. Position the new power supply on the alignment rails and slide it into the Library until it is flush with the
    back panel, as shown in Figure 108. Tighten the three blue thumbscrews to secure the power supply.
4. Attach an AC power cord to the replaced power supply and plug into a power outlet. Power on the
    Tape Library, if necessary.
5. Verify that the new power supply is operating properly.

Power supply LEDs
1. Blue AC power is connected.
2. Yellow Fan failure. The fan is running too slow or is defective.
3. Green The power supply is producing good power for the Library.

Use the packaging from the replacement power supply to return the failed power supply to Oracle.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Bring library and drives back online to Operating System and Software Application.

PARTS NOTE:
SL48 Sun Chassis w/o Tape Drive 380-1567

REFERENCE INFORMATION:
SL24/SL48 User and Service Guide
http://download.oracle.com/docs/cd/E25510_01/en/875-4225-11/875-4225-11.pdf