Technical Instruction Sure
Solution
1373574.1
:
CRU Replacement of Target Bezel for SDLT Tape Drive in L180/700/1400 Library:ATR:1373574.1:0
Related Items |
- Sun StorageTek L180 Tape Library
- Sun StorageTek L700e Tape Library
- Sun StorageTek L1400 Tape Library
- Sun Storage SDLT 220 Tape Drive
- Sun Storage SDLT 320 Tape Drive
- Sun StorageTek L700 Tape Library
- Sun Storage SDLT 600 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
|
In this Document
Applies to:
Sun StorageTek L700e Tape Library - Version Not Applicable and later
Sun StorageTek L1400 Tape Library - Version Not Applicable and later
Sun StorageTek L180 Tape Library - Version Not Applicable and later
Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun Storage SDLT 220 Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.
Goal
L180, L700, L1400/SDLT - CRU Replacement of Target Bezel for SDLT Tape Drive in L180/700/1400.
L180/L700/L1400 Target Bezel SDLT 313626304
L180/L700/L1400 Target Bezel SDLT 600 313930801
Fix
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Need to be familiar with L-Series Library and SDLT tape drive.
- TIME ESTIMATE: 60 minutes
- TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW:
Bezel on the SDLT tape drive is damaged / defective and requires replacement.
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
All work to the drive should be stopped. Drive should be offline to the OS and software application.
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:
SDLT/SDLT-600 Preparation:
If the drives are daisy-chained, stop all data processing in the channel before disconnecting them.
Warning:
Electrocution hazard: Do not tough any components on the power supply located within the electronics module or on the drive trays. Live voltage could be present even though the unit is powered off.
Removing the tape drive:
1. Make sure the SDLT drive is offline to any applications and the Operating System.
2. Open the right side door of the tape library.
3. Turn off the power to the drive by placing the switch in the off position.
4. Carefully remove the SCSI cable from the rear of the drive. The SCSI cable requires
the unscrewing of two SCSI cable screw locks.
5. Loosen the thumbscrew on the left side of the drive.
6. Grip the rear of the drive and, while pulling it toward you, place your other hand under the drive tray for
support.
7. Using both hands, remove the drive tray assembly from the slot, and place it on a flat, stable surface.
Caution:
Possible damage to bezel: the mounting tabs on the bezel are thin and easily broken. Be careful when following the next steps.
Removal of Bezel:
1. Tabs are visable and accessible at the lower right and left corners of the bezel. Lift upward on both tabs
to disengage from the drive face.
2. Rotate the bottom of the bezel away from the drive and upward until the upper tabs disengage from the
drive face.
Replacement of Bezel:
1. Orient the bezel with the target downward.
2. Tip the top of the bezel toward the drive face and engage the upper tabs.
3. Rotate the lower part of the bezel downward and toward the drive face until the lower tabs engage and
snap into place.
Replacement of drive:
Caution:
Possible equipment damage: When sliding the tape drive into its slot, make sure the drive SCSI or Fibre Channel cable is out of the way. Do not force the drive into the slot.
1. Slide the drive into its slot, being careful not to catch or crush any cables.
2. Tighten the thumbscrew on the left side of the drive.
3. Connect the SCSI cable screw locks to the SCSI connector on the rear of the drive.
4. Turn on the drive power by placing the switch to the on position.
5. Close the right side door of the library.
6. Return the system to operation.
The old bezel can be discarded as it is considered a consumable item.
Should you have any issues or questions, contact the Oracle Technical Support Center.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Bring SDLT tape drive back online to the Operating System and Software Application.
PARTS NOTE:
L180/L700/L1400 Target Bezel SDLT 313626304
L180/L700/L1400 Target Bezel SDLT 600 313930801
REFERENCE INFORMATION:
na
Attachments
This solution has no attachment