Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1373541.1
Update Date:2011-11-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  1373541.1 :   CRU Replacement of Target Bezel for HP LTO Drive in L180/700/1400 Library:ATR:1373541.1:0  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • HP LTO1 Tape Drive
  •  
  • HP LTO4 Tape Drive
  •  
  • HP LTO3 Tape Drive
  •  
  • Sun StorageTek L700e Tape Library
  •  
  • HP LTO2 Tape Drive
  •  
  • Sun StorageTek L1400 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Drives - LTO
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  




In this Document
  Goal
  Solution


Applies to:

HP LTO3 Tape Drive - Version: Not Applicable and later   [Release: N/A and later ]
HP LTO4 Tape Drive - Version: Not Applicable to N/A   [Release: N/A to ]
Sun StorageTek L180 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek L700 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek L700e Tape Library - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

L180, L700, L1400/HP LTO - CRU Replacement of Target Bezel for HP LTO Drive in L180/700/1400.

L180/L700/L1400 Target Bezel HP LTO1,2,3,4                   313622903

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Need to be familiar with the L-Series Library and LTO tape drive.

- TIME ESTIMATE: 60 minutes

- TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW:
Bezel on LTO tape drive is defective / damaged and needs to be replaced.

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
All work to LTO tape drive with problem should be stopped.  Place drive offline to OS and software application.

- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:
HP LTO Preparation:

If the drives are daisy-chained, stop all data processing in the channel before disconnecting them.

Warning:
Electrocution hazard: Do not tough any components on the power supply located within the electronics module or on the drive trays. Live voltage could be present even though the unit is powered off.

Removing the tape drive:
1. Make sure the LTO drive is offline to any applications and the Operating System.
2. Open the right side door of the tape library.
3. Turn off the power to the drive by placing the switch in the off position.
4. Carefully remove the SCSI or Fibre Channel cable from the rear of the drive. The SCSI cable requires
    the unscrewing of two SCSI cable screw locks.
5. Loosen the thumbscrew on the left side of the drive.
6. Grip the rear of the drive and, while pulling it toward you, place your other hand under the drive tray for
    support.
7. Using both hands, remove the drive tray assembly from the slot, and place it on a flat, stable surface.

Caution:
Possible damage to bezel: the mounting tabs on the bezel are thin and easily broken. Be careful when following the next steps.

Removal of the Bezel:


Note:

References to left and right tabs in this procedure are based on the normal (non-rotated) operating position of the drive and the bezel.

1. Press down on the two tabs as close to the drive face as possible.  Use a small screwdriver, if necessary.
2. While holding pressure, rotate the bezel away from the drive until the left tabs are clear of the drive
     faceplate.
3. Lift up on the bezel to release the right tabs from the faceplate.

Replacement of the Bezel:
4. Orient the bezel to so the target is on the bottom.
5. Insert the right tabs into the slots next to the cartridge slot.
6. Rotate the bezel against the drive faceplate and press until the left tabs snap into place.
8. Check that the bezel is against the drive faceplate at the left end.

Caution:
Possible equipment damage: When sliding the tape drive into its slot, make sure the drive SCSI or Fibre Channel cable is out of the way. Do not force the drive into the slot.

9. Slide the drive into its slot, being careful not to catch or crush any cables.
10. Tighten the thumbscrew on the left side of the drive.
11. For SCSI drives, connect the SCSI cable screw locks to the SCSI connector on the rear of the drive.
      Otherwise, plug the Fibre Channel connector into the drive.
12. Turn on the drive power by placing the switch to the on position.
13. Close the right side door of the library.
14. Return the system to operation.

The old bezel can be discarded as it is considered a consumable item.

Should you have any issues or questions, contact the Oracle Technical Support Center.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Bring drive online to Operating System and Software Application.

PARTS NOTE:
L180/L700/L1400 Target Bezel HP LTO1,2,3,4 313622903

REFERENCE INFORMATION:
na

Attachments