![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1361969.1 : SL3000 - Re-Enable ILC and Check ComplexId After FRS-3.0 Code Upgrade
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun StorageTek SL3000 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. GoalSL3000 - Re-Enable ILC and Check ComplexId After FRS-3.0 Code Upgrade( Inner Library Communication ) SolutionAfter upgrading to FRS-3.0 code from older versions you need to check via the CLI that the ILC is still enabled and also check the setting of the complexId.If you use SDP and/or use Port 1A for service, this is important to check. Commands to check/set these values: For COMPLEXID config complexId print Prints the current SDP complex ID config complexId set [1-254] Sets the complexId to the specific number for SDP (default is "1") For ILC config ilc print prints ilc status config ilc enable | disable enable or disable the ilc Provided by Rich Kent. Attachments This solution has no attachment |
||||||||||||
|