Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1349706.1
Update Date:2011-11-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1349706.1 :   How to Remove and Replace a Ultra 24 Workstation PCI Card:ATR:1349706.1:0  


Related Items
  • Sun Ultra 24 Workstation
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Ultra 24 Workstation - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

How to Remove and Replace a Ultra 24 Workstation PCI Card

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED: Nothing beyond basic hardware and Solaris training
- TIME ESTIMATE: 60 minutes
- TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: How to Remove and Replace a Ultra 24 Workstation PCI Card
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Remove a PCI Card

1. Powering Off the System and Removing the Left-Side Access Panel.
   I. Power off the system and all the peripherals connected to it.
   II. Turn the power switch on the back of the chassis to the Off position.
caution icon Caution - Failure to properly turn off the system before you start installing components can cause serious component damage.
   III. To maintain system grounding, do not unplug the AC power cord from the back of the system   unless the specific procedure instructs you to unplug it.
   IV. Loosen the two captive thumbscrews located on the rear edge of the left side access panel
   V. Slide the access panel approximately 1.5 cm toward the back of the workstation.
   VI. Tilt the top edge of the panel out, then lift the panel upward.
   VII. Carefully set the panel aside.

2. Gently lay the system on its right side on a stable, nonslip surface.
3. Remove any cables connected to the card.
4. Unscrew the PCI card retainer screw.
5. Remove the PCI card.

Install a PCI Card

Note - Any 64-bit PCI cards that you install will run in 32-bit mode.
1. Gently lay the system on its right side on a stable, nonslip surface.
2. See the service label on the access panel to determine a slot that is compatible with the card you are installing.
3. Remove the metal bracket cover for the slot from the back panel.
4. Remove the PCI card from its protective packaging and lay the card on an antistatic surface until you are ready to install it.
5. Position the card over the selected slot.
7. Press down on the card until it is completely seated in the slot.
8. Fasten the retaining screw into place. Torque the screws to 8 to 9 inch-pounds.
9. Close the system by performing the steps in To Prepare for Service.

Gently rock the PCI card forward and then lift it straight out of the PCI card slot and set it aside on an antistatic surface.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:Power on the system, and verify the installation

PARTS NOTE:

REFERENCE INFORMATION:

Sun Ultra 24 Workstation Service Manual
http://download.oracle.com/docs/cd/E19127-01/ultra24.ws/820-2480-12/


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback