Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1349652.1
Update Date:2011-11-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1349652.1 :   How to Remove and Replace a Ultra 24 Workstation Memory DIMMs:ATR:1349652.1:0  


Related Items
  • Sun Ultra 24 Workstation
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Ultra 24 Workstation - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

How to Remove and Replace a Ultra 24 Workstation Memory DIMMs

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED: Nothing beyond basic hardware and Solaris training
- TIME ESTIMATE: 60 minutes
- TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:  How to Remove and Replace a Ultra 24 Workstation Memory DIMMs
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Powering Off the System and Removing the Left-Side Access Panel.

I. Power off the system and all the peripherals connected to it.
II. Turn the power switch on the back of the chassis to the Off position.
caution icon Caution - Failure to properly turn off the system before you start installing components can cause serious component damage.
III. To maintain system grounding, do not unplug the AC power cord from the back of the system unless the specific procedure instructs you to unplug it.
IV. Loosen the two captive thumbscrews located on the rear edge of the left side access panel
V. Slide the access panel approximately 1.5 cm toward the back of the workstation.
VI. Tilt the top edge of the panel out, then lift the panel upward.
VII. Carefully set the panel aside.

Remove DIMMs

1. Gently lay the system on its right side on a stable, nonslip surface.
2. Identify the location from which you will remove a DIMM
3. Place your forefingers on the top of the DIMM.
4. Remove the DIMM by pressing down on the ejector bars at both ends of the DIMM socket
5. Set the DIMM aside on an antistatic surface.
6. Choose the next step.        

■ If you are installing a new DIMM, see “Installing DIMMs” on page 61 of the Service Manual.
■ If you are finished, replace the left side access panel.

 

Installing DIMMs

When you install a DIMM in the workstation, keep the following guidelines in mind:
   * DIMM slots are numbered 0 to 3. Slot 0 is closest to the CPU
   * DIMMs must be installed and removed in pairs
   * Populate DIMM slot 1 and DIMM slot 3, then DIMM slot 0 and DIMM slot 2
   * For a single DIMM configuration use DIMM slot 1
2. Gently lay the system on its right side on a stable, nonslip surface.
3. Identify the location into which you will install a DIMM.
4. Align the DIMM with the proper slot.
Note - Be sure to align the notch in the DIMM with the notch in the connector.
5. Place the DIMM in the slot.
6. Evenly press the DIMM straight down into the DIMM slot until both ejector levers lift and click, locking the DIMM in the DIMM slot.
Note - The DIMM is seated when you hear a click and the DIMM ejector levers are in the vertical position.
7. Repeat Step 3 through Step 6 for each DIMM that you want to replace.

The system automatically detects the amount of memory installed. Run the BIOS setup to view the new value for total system memory and make a note of it.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:Power on the system, and verify the installation

PARTS NOTE:

REFERENCE INFORMATION:

Sun Ultra 24 Workstation Service Manual
http://download.oracle.com/docs/cd/E19127-01/ultra24.ws/820-2480-12/


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback