Solution Type Technical Instruction Sure Solution 1349619.1 : How to Remove and Replace a Sun Fire X2270 M2 SP Module:ATR:1349619.1:0
In this Document
Applies to:Sun Fire X2270 M2 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. GoalHow to remove and replace a Sun Fire X2270 M2 SP ModuleSolutionDISPATCH INSTRUCTIONS- WHAT SKILLS DOES THE ENGINEER NEED: - TIME ESTIMATE: 5 minutes - TASK COMPLEXITY: 0 FIELD ENGINEER INSTRUCTIONS: - PROBLEM OVERVIEW: Removing and Installing the SP Module - WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: System should be powered off prior to service. - WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Remove 1 Prepare the server for service. See How to Prepare for Service. 2 Remove the air duct. See How to Remove the Air Duct. 3 Remove any cables that are attached to the rear of the SP module. 4 Completely loosen the captive screw securing the SP module to the server motherboard. 5 Pull the SP module upward to disengage the card from the connector and the alignment pin on the motherboard. 6 To remove the SP module, slide it slightly forward to clear the rear wall of the server chassis, and then lift the module from the chassis. 7 If you are replacing the SP module, see How to Install the SP Module. 8 Prepare the server for operation. See How to Prepare for Operation. Install 1 Slide the SP module alignment pin over the screw post before installing the SP module. The SP module alignment pin is designed to help align the SP module with the card connector. The SP module alignment pin is shipped with the SP module. 2 Position the SP module so the card’s RJ-45 and HD15 connectors face the rear of the server. 3 Align connectors on the SP board with the openings in the rear panel of the server chassis. 4 Use the alignment pin to align the connector on the SP module with the connector on the motherboard. 5 Gently push down on the SP module to engage the connector on the module with the connector on the motherboard. 6 Tighten the captive screw to secure the SP module. 7 Install the air duct. See How to Install the Air Duct. 8 Prepare the server for operation. See How to Prepare for Operation. OBTAIN CUSTOMER ACCEPTANCE - WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Power the system on. PARTS NOTE: REFERENCE INFORMATION: Location of Internal Server Components Sun Fire X2270 M2 Server Service Manual http://download.oracle.com/docs/cd/E19902-01/821-1345/ Attachments This solution has no attachment |
||||||||||||
|