Goal

How to remove and replace a Sun Fire X2270 M2 Power Supply

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:  Removing and Installing a Power Supply

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
System should be powered off prior to service.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Remove
1 Prepare the server for service. See How to Prepare for Service.
2 Remove the power supply. See How to Remove the Power Supply.
3 Reference the following illustration for this procedure.
4 Disconnect the three power supply cables from the motherboard.
5 Disconnect the power supply cable from the hard drive backplane and push the cable through the cutout in the chassis divider.
6 Loosen the captive screw that secures the power supply to the chassis.
7 Lift the power supply out of the chassis.

Install
1 Reference the following illustration for this procedure.
2 Insert the power supply into the chassis with the cable bundle toward the front of the server.
3 To secure the power supply to the chassis, fully tighten the captive screw.
4 Route the HD/SSD power cable through the opening in the chassis divider.
5 Connect three of the power supply cables to the motherboard.
6 Connect the power supply cable to the hard disk backplane.
7 Install the power. See How to Install the Power Supply.
8 Prepare the server for operation. See How to Prepare for Operation.


OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Power the system on.

PARTS NOTE:

REFERENCE INFORMATION:
Sun Fire X2270 M2 Server Internal Cabling
Locations of Internal Server Components

Sun Fire X2270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19902-01/821-1345/