Solution Type Technical Instruction Sure Solution 1349587.1 : How to Remove and Replace a Sun Fire X2270 M2 Hard Drive Filler and Hard Drive Assembly:ATR:1349587.1:0
In this Document
Applies to:Sun Fire X2270 M2 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. GoalHow to remove and replace a Sun Fire X2270 M2 Hard Drive Filler and Hard Drive AssemblySolutionDISPATCH INSTRUCTIONS- WHAT SKILLS DOES THE ENGINEER NEED: - TIME ESTIMATE: 20 minutes - TASK COMPLEXITY: 0 FIELD ENGINEER INSTRUCTIONS: - PROBLEM OVERVIEW: Removing and Installing a Hard Drive Filler and Hard Drive Assembly - WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: - WHAT ACTION DOES THE ENGINEER NEED TO TAKE: 1 For the drive slot in which you want to install a removable hard drive, rotate the release lever on the front of the filler to disengage the hook and extend the handle. 2 Use the handle to pull the filler out of the slot. Remove 1 Power off the server. See How to Power Off the Server. Note - If you are using an integrated-mirroring (IM) configuration, you do not need to power off the server before removing a hard drive, but you must ensure that the drive is disconnected from the OS and ready to be removed. 2 On the drive you want to remove, push the release button to open the latch and extend the latch to its fully-open position. Note - The latch is not an ejector. Do not bend it too far to the right. Doing so may damage the latch. 3 To remove the drive, us the handle to pull the drive out of the drive slot. 4 If you are replacing the drive, go to How to Install a Removable Hard Drive Assembly. 5 If you are not replacing the drive, install a filler panel. See How to Install a Hard Drive Filler. 6 Power on the server. See How to Power On the Server. Install 1 Power off the server. See How to Power Off the Server. 2 Ensure that the latch on the hard drive assembly is in the fully open position. To open the latch, press the latch release button on the front of the assembly. 3 Slide the drive into the drive slot until it is fully seated and flush with the front of the server. 4 Close the latch. 5 Power on the server. See How to Power On the Server reconfigure the disk into the operating system and mirrored configuration. OBTAIN CUSTOMER ACCEPTANCE - WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: PARTS NOTE: REFERENCE INFORMATION: How to Remove a Hard Drive Filler How to Install a Hard Drive Filler How to Install a Removable Hard Drive Assembly Sun Fire X2270 M2 Server Service Manual http://download.oracle.com/docs/cd/E19902-01/821-1345/ Detailed SVM instructions can be found at http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html See Document 1010946.1 for Detailed Veritas Volume Manager instructions. See Document 1002753.1 for Detailed ZFS instructions References<NOTE:1010946.1> - General Guidance for Diagnosis and Replacing SCSI/SAS/SATA/FC-AL Disks running on Oracle Servers with Solaris<NOTE:1002753.1> - How to replace a drive in Solaris[TM] ZFS Attachments This solution has no attachment |
||||||||||||
|