Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1349250.1
Update Date:2011-11-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1349250.1 :   How to Remove and Replace Sun Fire X2270 M2 DIMMs:ATR:1349250.1:0  


Related Items
  • Sun Fire X2270 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire X2270 M2 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Information in this document applies to any platform.

Goal

How to Remove and Replace Sun Fire X2270 M2 DIMMs

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: How to remove and replace a DIMM

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1 Prepare the server for service. See How to Prepare for Service.
2 Remove the air duct. See How to Remove the Air Duct.
3 Locate the DIMM socket in which you want to install or replace a memory module. See DIMM Slot Designations.
4 Eject the DIMM from the slot by simultaneously pressing down on the ejector levers at both ends of the DIMM socket.
This action releases the DIMM from the slot.
5 To remove the DIMM, lift it up and out of the socket.
6 Install the replacement DIMM ensuring that the DIMM is properly rotated to allow the "key" to sit correctly.
7 Replace the air duct and replace the top cover.
8 Return the server to operation. See How to Prepare for Operation

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Power on and boot the system.

PARTS NOTE:

REFERENCE INFORMATION:

How to Remove a DIMM
How to Install a DIMM
Error Correction and Parity
DIMM Population Rules

Sun Fire X2270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19902-01/821-1345/