Goal
Fix


Applies to:

HP LTO4 Tape Drive - Version Not Applicable and later
HP LTO5 Tape Drive - Version Not Applicable and later
Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Sun StorageTek SL24 Tape Autoloader - Version Not Applicable and later
Sun StorageTek SL48 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.

Goal

Supported SAS HBAs for SL24 and SL48 library.

In the SSH, there are HBAs for FC but nothing for SAS under the SL24 and SL48 parts list.

Fix

SL24/SL48 have been fully qualified with all SAS HBAs Oracle supports.  The HBA used depends on the OS and application installed.

Dione:      SAS-1 PCI-X bus, SG-XPCI8SAS-E-Z
Pandora:  SAS-1 PCI-Express bus, SG-XPCIE8SAS-E-Z
Mimas:     SAS-1 PCI-EM bus, SG-XPCIE8SAS-EB-Z
Erie:         SAS-2 PCI-Express bus, SGX-SAS6-EXT-Z
Erie:         SAS-2 PCI-EM bus, SGX-SAS6-EM-Z

The Erie SAS-2 Solaris driver has a couple of issues. 

1.  Need Solaris 10 Update 10 for sgen, otherwise the robot will not be discovered (CR 6991467)
2.  Because of the new Solaris mpt_sas driver for the Erie SAS-2 HBA, most backup apps are unable to discover the robot and drives (CR 6989444)

For these reasons we do not support the Erie SAS-2 on Solaris at this time. (Aug, 2011)

Note: 4-Jan-2012
The Erie SAS 2 HBA isn't supported with the LTO5 SAS 2 drives on Solaris.