Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1349239.1
Update Date:2011-11-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1349239.1 :   How to Remove and Replace a Sun Fire X2270 M2 PCIe Card:ATR:1349239.1:0  


Related Items
  • Sun Fire X2270 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire X2270 M2 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Information in this document applies to any platform.

Goal

How to remove and replace Sun Fire X2270 M2 PCIe Card

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

REMOVING
1 Prepare the server for service. See How to Prepare for Service.
2 Remove the air duct. See How to Remove the Air Duct.
3 Disconnect any cables connected to the PCIe card.
4 To unlock the PCIe card, open the locking latch on the server rear panel.
5 To remove the PCIe card from the server, slide the card out of the server rear panel and disconnect the card from the PCIe riser.
6 Remove any card-specific cabling from the server.
7 Install the air duct. See How to Install the Air Duct.
8 Prepare the server for operation. See How to Prepare for Operation.

INSTALL
1 Prepare the server for service. See How to Prepare for Service.
2 Remove the air duct. See How to Remove the Air Duct.
3 If necessary, pull open the locking latch on the rear panel of the server to unlock the PCIe filler panel.
4 Remove the filler panel by lifting it straight up and out of the server.
5 If a PCIe riser is not already installed in the server, install a PCIe riser. See How to Install the PCIe Riser.
The PCIe riser is a low-profile, half-length x16 connector card.
6 Slide the new PCIe card into the PCIe slot on the rear panel of the server and connect the card to the PCIe riser.
7 To lock the PCIe card, push to close the locking latch on the rear panel of the server.
8 Attach any required internal cabling to the card.
9 Install the air duct. See How to Install the Air Duct.
10 Prepare the server for operation. See How to Prepare for Operation.

OBTAIN CUSTOMER ACCEPTANCE

- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:

Sun Fire X2270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19902-01/821-1345/

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.