Asset ID: |
1-71-1347632.1 |
Update Date: | 2012-07-26 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347632.1
:
How to Remove and Replace a X4170 M2 FAN MODULE:ATR:2106:0
Related Items |
- Oracle Exalogic Elastic Cloud X2-2 Hardware
- Exadata Database Machine X2-2 Qtr Rack
- Exadata Database Machine X2-2 Half Rack
- Exadata Database Machine X2-2 Full Rack
- Exadata Database Machine X2-2 Hardware
- Oracle Exalogic Elastic Cloud X2-2 Full Rack
- Oracle Exalogic Elastic Cloud X2-2 One-Eighth Rack
- Sun Fire X4170 M2 Server
- Oracle Exalogic Elastic Cloud X2-2 Qtr Rack
- Oracle Exalogic Elastic Cloud X2-2 Half Rack
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4170 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Exadata Database Machine X2-2 Hardware - Version Not Applicable and later
Exadata Database Machine X2-2 Qtr Rack - Version Not Applicable and later
Exadata Database Machine X2-2 Half Rack - Version Not Applicable and later
Exadata Database Machine X2-2 Full Rack - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a X4170 M2 FAN MODULE
Fix
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED: General Sun X64 Servers Knowledge
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: Fan Module Replacement
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
Caution - Hazardous moving parts*.* Unless the power to the server is completely shut down, the only service permitted in the fan compartment is the replacement of the fan modules.
Removing the fan modules
Caution – Hazardous moving parts. When removing the fans, be careful of the fan blades.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing Fan Module
1. Extend the server into the maintenance position.
2. To access the fans, open the top cover fan door.
To release the fan door, push the top cover release tabs toward the back of the server and lift the door to the open position.
3. Identify the faulty fan module(s).
Each fan module has a status LED on top. If the LED is amber, the fan has failed.
4. Remove the faulty fan module(s).
a. Using your thumb and forefinger, grasp the fan module in the finger recesses located in the white plastic between the fans and compress the fan module release latch.
b. Lift the fan module straight up and out of the fan board.
Installing Fan Module
1. With the top cover door open, install the replacement fan module into the server.
The fan modules are keyed to ensure that they are installed in the correct
orientation.
2. Press down on the fan module and apply firm pressure to fully seat the fan
module.
3. Verify that the Fan status LED on the replaced fan module is lit green.
4. Close the top cover door.
5. Verify that the TOP FAN LED on the front of the server and the Service Action
Required LEDs on the front and rear of the server are extinguished.
6. Return the server to the normal rack position.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
N/A
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170_M2/components.html#Fan
REFERENCE INFORMATION:
Sun Fire X4170 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19762-01/E22369-02/index.html
Attachments
This solution has no attachment