Solution Type  Technical Instruction Sure

Solution  1347629.1 :   How to Remove and Replace a X4170 M2 Power Supply Unit:ATR:2102:0  


Related Items
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Full Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 One-Eighth Rack
  •  
  • Sun Fire X4170 M2 Server
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Qtr Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Half Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Fire X4170 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Exadata Database Machine X2-2 Hardware - Version Not Applicable and later
Exadata Database Machine X2-2 Qtr Rack - Version Not Applicable and later
Exadata Database Machine X2-2 Half Rack - Version Not Applicable and later
Exadata Database Machine X2-2 Full Rack - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a X4170 M2 PSU

Fix

DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED: General Sun X64 Servers Knowledge.

TASK COMPLEXITY: 0

TIME ESTIMATE: 30 minutes

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: Power Supply Replacement
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
If the server has a redundant power supply, you are able to remove or install the power supply without shutting down the server, provided that the other power supply is online and working.
If the server have not this redundant unit, the server must be offline.

If a power supply fails and you do not have a replacement available, to ensure proper airflow, either leave the failed power supply installed in the server or
remove the failed power supply and install a filler panel.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Attach an antistatic wrist strap.

2. Identify which power supply (0 or 1) requires replacement.

3. Disconnect the power cord from the faulty power supply.

4. Grasp the power supply handle and press the release latch

5. Pull the power supply out of the chassis.

6. Installation is the reverse of this procedure.

Caution – Whenever you remove a power supply, you should replace it with
another power supply or a filler panel; otherwise, the server might overheat due to
improper airflow.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Restart system and have the system administrator verify functionality of system.


PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170_M2/components.html#Power

REFERENCE INFORMATION:
Sun Fire X4170 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19762-01/E22369-02/index.html