Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1347168.1
Update Date:2011-11-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  1347168.1 :   How to Remove and Replace a Netra 440 Power Supply:ATR:1835:0  


Related Items
  • Sun Netra 440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Netra 440 Server - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

How to Remove and Replace a Netra 440 Power Supply

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED: Basic Netra 440 Training
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: Failed Power Supply

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
If single power supply configuration or both in dual power supply are failed system should be down & powered off.
If a dual supply system in which one is failed, one can use Hotplug replacement & system need not be shut down, but operational precautions such as data protection or user notification may be necessary to comply w/ customer operational guidelines.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Cold replacement:
1 Take appropriate ESD procedures
2 Identify power supply to be removed
3 Pull out power supply in smooth motion until free of bay
4 Align new power supply with its bay

5 Slide new power supply into power supply bay until power supply connectors start to engage connectors on motherboard

6 Push firmly on front of power supply to engage power supply connectors with motherboard connectors
7 For systems with older ALOM firmware (prior revision 1.5.4), the replacement power supply must be enabled with ALOM command: poweron PS# where # corresponds to the power supply that was replaced.

Hot-plug replacement:
NOTE - You have limited time to perform power supply hot-plug operation. You
have 10 minutes @ sea level & a maximum of 7 minutes @ 10,000 feet (3048
meters) to ensure proper system cooling. Do not remove failed supply nor begin the Hotplug procedure unless you have replacement part available for immediate insertion.
1 Take appropriate ESD procedures
2 Identify power supply to be removed

3 Type following ALOM command: sc> removefru PS# (where # corresponds to the PSU to be replaced)
CAUTION - Do not remove a PSU from a running system until PSU OK-to-Remove LED is lit
4 Pull out power supply in a smooth motion until free of bay
5 Align new power supply with its bay
6 Slide new power supply into power supply bay until power supply connectors start to engage connectors on motherboard
7 Push firmly on front of power supply to engage power supply connectors with motherboard connectors

8 For systems with older ALOM firmware (prior revision 1.5.4), the replacement power supply must be enabled with ALOM command: poweron PS# where # corresponds to the power supply that was replaced.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
For successful hot-plug replacement, none
For successful cold replacement, boot system & start applications

PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/Netra_440/components.html#Power

REFERENCE INFORMATION:
Netra 440 Server Service Manual:
http://download.oracle.com/docs/cd/E19102-01/n440.srvr/817-3883-12/index.html

Netra 440 Server System Administration Guide:
http://download.oracle.com/docs/cd/E19102-01/n440.srvr/817-3884-11/index.html