Solution Type  Technical Instruction Sure

Solution  1345676.1 :   How to Remove and Replace X2200 M2 Optical Disk Drive Cable Assembly:ATR:1345676.1:0  


Related Items
  • Sun Fire X2200 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire X2200 M2 Server - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

To replace an Optical Disk Drive (ODD) Assembly

Solution

CAP PROBLEM OVERVIEW: How to Remove and Replace an Optical Disk Drive (CD or DVD) Assembly

WHAT SKILLS DOES THE ENGINEER NEED?
ESD Awareness and basic hardware competence

Task Complexity: 0

Time Estimate: 120 minutes

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?

o Power off the system and remove the cover
o Unfasten the drive ribbon cable from the Optical Disk Drive (ODD).
o Caution - Use care with the small flat cables. They are extremely fragile.
o Push the latch on the back of the ODD drive toward the drive until the ODD drive springs forward out of the chassis.
o Pull the ODD drive out the front of the chassis.
o Caution: Move the assembly by grasping it by its sides. Do not push on the DVD-ROM tray.
o To Install the ODD Drive Assembly
o If necessary, remove the filler panel in front of the ODD drive slot on the front panel. Put your finger or a screw driver behind the slot on the right side of the filler panel and pull the panel outward.
o Position the ODD drive in front of the ODD drive slot on the front panel.
o Push the ODD drive into the drive slot until the drive clicks into place.
o Reinstall the ODD drive cable.
o Check the routing of all cables for obstructions, and then reinstall the cover.


7. WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM
TO AN OPERATIONAL STATE?
Power on the server

8. ANY PARTS NOTES?

9. REFERENCE INFORMATION
http://download.oracle.com/docs/cd/E19121-01/sf.x2200m2/819-6597-12/index.html