![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1345652.1 : How To Remove and Replace X2200 M2 Single Fans:ATR:1345652.1:0
In this Document
Applies to:Sun Fire X2200 M2 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. GoalTo Replace Single FansSolutionCAP PROBLEM OVERVIEW: How to Remove and Replace Single FansWHAT SKILLS DOES THE ENGINEER NEED? ESD Awareness and basic hardware competence Task Complexity: 0 Time Estimate: 90 minutes WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? Power off the system and remove the cover Identify the fan to be replaced. Pull the fan upward to remove it. Unplug the fans power connector from the connector on the fan harness. To Install a Fan Module Position the fan so that the arrow on top of the fan casing is facing the middle chassis divider. Place the fan in the chassis so that it fits over the small guideposts. Gently push the fan down to secure it to the chassis. Connect the fan connector to the appropriate connector on the fan harness. Check the routing of all cables for obstructions, and then reinstall the cover. 6. WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE? Power on the system. 7. ANY PARTS NOTES? 8. REFERENCE INFORMATION http://download.oracle.com/docs/cd/E19121-01/sf.x2200m2/819-6597-12/index.html Attachments This solution has no attachment |
||||||||||||
|