Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1342322.1
Update Date:2011-12-02
Keywords:

Solution Type  Technical Instruction Sure

Solution  1342322.1 :   How to set the serial number using the utility sdfru  


Related Items
  • Sun Fire X4150 Server
  •  
  • Sun Fire X4250 Server
  •  
  • Sun Netra X4450 Server
  •  
  • Sun Fire X2250 Server
  •  
  • Sun Netra X4250 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Server>SN-x64: MISC-SERVER
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>x64 Servers
  •  




In this Document
  Goal
  Solution


Created from <SR 3-4049624841>

Applies to:

Sun Fire X4150 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Netra X4250 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire X4250 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Netra X4450 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire X2250 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.
This only applies to Sun Fire X4150, Sun Fire X4250, Netra X4250, Sun Fire X4450

Goal

After a motherboard replacement, the serial number is all zeros, or incorrectly matches the chassis.
For example:
-> show /SYS
/SYS
Properties:
type = Host System
ipmi_name = /SYS
product_name = SUN FIRE X4150
product_part_number = 602-4252-01
product_serial_number = 0000000000
product_manufacturer = SUN MICROSYSTEMS
power_state = On

Solution

Use the sdfru utility, which is available in the \utility\sdfru directory of the Tools and Driver release disc when booted into DOS.
You will need to shutdown your operating system, in order to boot from the Tools and Drivers CD/DVD (available in patch 11843046).
Once booted, you will see 3 options:
  1. Run Hardware Diagnostics
  2. Erase Primary Boot Hard Disk
  3. Exit to DOS

Choose option 3 to exit to DOS

Then change directory to utility\sdfru and execute sdfru:
cd utility\sdfru
sdfru

Prompts and output will be similar but not identical to the following:
[Version_3.0.0] C:\UTILITY\SDFRU>sdfru -m3 -ssn 0807TST054
SDFru v1.11
System identified as Sun Fire X4150
Reading current FRU PROM contents...Done
Enter PPN: 602-4252-01      <<<<<<<<<<<<<<<<<<<< you can get this from show /SYS command on the ILOM
Setting System Serial Number to: 0807TST054
Setting Product Part Number to : 602-4252-01
Extra Segment Updated
Writing FRU prom... Done (System and SP restart is needed to take affect)


Here is the sdfru readme for syntax explanation:
SDFru v1.00
System identified as Sun Fire X4150/X4250
sdfru:
-i <File> Input filename for some operations
-o <File> Output filename for some operations
-l Display the prom serial numbers and part numbers
-read Raw Read the FRU PROM and save to filename (no checking)
-extract Extract prom contents and prepare files for upload (may require doslfn.com)
-m1 Board Level Mode (don't accept system level info)
-m3 System Level Mode (don't accept board level info)
-vid XXXX Use <XXXX> as vendor ID
-hwrev RR Use value as Initial HW Rev Level
-ssn SSN Use value as SSN (accepts dashes or no dashes)
-ppn PPN Use value as 602 product part number (accepts dashes or no dashes)
-fsn FSN Use value as FRU serial number, otherwise use input file value
-mac ADDR Use value as the base MAC address of host port 0 (no colons)
-bmcmac ADDR Use value as the base MAC address of host port 0 (no colons)
-elom Use legacy ELOM interface (x4150, X4250 only)
-v Display verbose information
-h Display this screen